A biaxial strain-based expansion mechanism for auxetic stent deployment.
BACKGROUND: Auxetics, a special class of materials, tend to expand both in the radial and longitudinal directions when a unidirectional tensile force is applied. Recently, studies have come up with new designs for auxetic vascular and nonvascular stents which are deployed with commercial balloon catheters. There are some inherent limitations associated with a unidirectional application of expansion force in the effective deployment of stents. This work proposed a solution to some of these limitations through the use of a biaxial mode of a predetermined strain-based expansion mechanism.
METHOD: The design incorporated a pressure-activated crank-slider mechanism. Fabrication of a prototype for experimental verification was carried out through milling and high-speed lathe machining. The testing of the device employed the use of auxetic stents, fabricated from a biocompatible polymer. A finite element study is presented to extrapolate experimental results to a broader range of operation and working conditions.
RESULTS AND CONCLUSIONS: The expansion mechanism is similar in operation to the opening of an umbrella. The length of the connected auxetic stent increases when internal hydraulic pressure is applied. The degree of linear expansion in 1 direction influences the expansion of auxetic stent in the lateral direction. As the device exerts pressure longitudinally, a larger amount of the force is distributed on the unit cells/hinges which ultimately results in an increased expansion of the stent.
METHOD: The design incorporated a pressure-activated crank-slider mechanism. Fabrication of a prototype for experimental verification was carried out through milling and high-speed lathe machining. The testing of the device employed the use of auxetic stents, fabricated from a biocompatible polymer. A finite element study is presented to extrapolate experimental results to a broader range of operation and working conditions.
RESULTS AND CONCLUSIONS: The expansion mechanism is similar in operation to the opening of an umbrella. The length of the connected auxetic stent increases when internal hydraulic pressure is applied. The degree of linear expansion in 1 direction influences the expansion of auxetic stent in the lateral direction. As the device exerts pressure longitudinally, a larger amount of the force is distributed on the unit cells/hinges which ultimately results in an increased expansion of the stent.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
Perioperative echocardiographic strain analysis: what anesthesiologists should know.Canadian Journal of Anaesthesia 2024 April 11
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app