We have located links that may give you full text access.
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
VALIDATION STUDIES
Intraoperative image guidance in transoral robotic surgery: A pilot study.
Head & Neck 2017 October
BACKGROUND: Intraoperative image guidance during transoral robotic surgery (TORS) is hampered by imaging-friendly instrumentation and intraoperative positioning. The purpose of this study was to develop and validate an accurate image-guidance system for TORS.
METHODS: A custom radiolucent mouth retractor was fabricated from biocompatible material (Med-610; Stratasys, Minneapolis, MN). Teflon beads were placed in the oropharynx and carotid arteries of 3 cadavers. CT scans were obtained in the preoperative and intraoperative positions. Displacement of targets between preoperative and intraoperative scans was measured. Surgical navigation was based on the open-source Image-Guided Surgery Toolkit. Target registration error (TRE) was determined by measuring the distance between the tracker and bead registered to preoperative versus intraoperative scans.
RESULTS: The inferior oropharyngeal targets demonstrated the greatest displacement between positions. A significant reduction in TRE was observed when registering the tracker to the intraoperative compared to the preoperative scan.
CONCLUSION: This study describes an accurate intraoperative image-guidance system for TORS.
METHODS: A custom radiolucent mouth retractor was fabricated from biocompatible material (Med-610; Stratasys, Minneapolis, MN). Teflon beads were placed in the oropharynx and carotid arteries of 3 cadavers. CT scans were obtained in the preoperative and intraoperative positions. Displacement of targets between preoperative and intraoperative scans was measured. Surgical navigation was based on the open-source Image-Guided Surgery Toolkit. Target registration error (TRE) was determined by measuring the distance between the tracker and bead registered to preoperative versus intraoperative scans.
RESULTS: The inferior oropharyngeal targets demonstrated the greatest displacement between positions. A significant reduction in TRE was observed when registering the tracker to the intraoperative compared to the preoperative scan.
CONCLUSION: This study describes an accurate intraoperative image-guidance system for TORS.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app