We have located links that may give you full text access.
Total and ionized magnesium testing in the surgical intensive care unit - Opportunities for improved laboratory and pharmacy utilization.
Journal of Critical Care 2017 December
PURPOSE: Ionized fraction (iMg) is the physiologically active form of magnesium (Mg); total Mg may not accurately reflect iMg status. Erroneously "low" Mg levels may result in unnecessary repetitive testing.
MATERIALS AND METHODS: From 11/2015 to 01/2016, patients ordered for Mg from a pilot ICU also had iMg tested. Weighted kappa statistic was used to assess agreement between Mg categories (low, normal, high). Predictors of unnecessary repeated Mg testing and repletion using data were explored through logistic regression models using GEE techniques to account for repeated measurements in both bivariate and multivariable analyses.
RESULTS: There were 470Mg/iMg paired measurements from 173 patients. The weighted kappa statistic was 0.35 (95%CI 0.27-0.43) indicating poor agreement in assessment of magnesium status. Of the 34Mg samples reported as "low", only 6 (18%) were considered "low" using concurrent iMg testing. In the multivariable models, history of atrial fibrillation (aOR=1.61, 95%CI 1.16-2.21, p=0.004) and concomitant metoclopramide (aOR=1.71, 95%CI 1.03-2.81, p=0.036) were significant predictors of unnecessary repeat Mg testing.
CONCLUSIONS: In the surgical ICU, categorical agreement (low, normal, high) was poor between Mg and iMg. Over 80% of "low" total Mg values are erroneous and may result in unnecessary additional measurements and repletion.
MATERIALS AND METHODS: From 11/2015 to 01/2016, patients ordered for Mg from a pilot ICU also had iMg tested. Weighted kappa statistic was used to assess agreement between Mg categories (low, normal, high). Predictors of unnecessary repeated Mg testing and repletion using data were explored through logistic regression models using GEE techniques to account for repeated measurements in both bivariate and multivariable analyses.
RESULTS: There were 470Mg/iMg paired measurements from 173 patients. The weighted kappa statistic was 0.35 (95%CI 0.27-0.43) indicating poor agreement in assessment of magnesium status. Of the 34Mg samples reported as "low", only 6 (18%) were considered "low" using concurrent iMg testing. In the multivariable models, history of atrial fibrillation (aOR=1.61, 95%CI 1.16-2.21, p=0.004) and concomitant metoclopramide (aOR=1.71, 95%CI 1.03-2.81, p=0.036) were significant predictors of unnecessary repeat Mg testing.
CONCLUSIONS: In the surgical ICU, categorical agreement (low, normal, high) was poor between Mg and iMg. Over 80% of "low" total Mg values are erroneous and may result in unnecessary additional measurements and repletion.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app