JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Iterative Reconstruction May Improve Diagnosis of Gout: An Ex Vivo (Bio)Phantom Dual-Energy Computed Tomography Study.

OBJECTIVES: We hypothesize that, compared with filtered back projection (FBP), iterative reconstruction (IR) increases the detected volume of uric acid, which serves as a measure of the sensitivity of the method, and therefore allows examinations with lower radiation exposure. Thus, the aim of our study was to evaluate the role of IR in dual-energy computed tomography (DECT) for gout assessment and volumetry in an ex vivo gout model using an epoxy phantom and a biophantom.

MATERIALS AND METHODS: We prepared specimens with different concentrations of monosodium uric acid in ultrasound gel (30%-50%) and inserted them into an epoxy-based phantom and a porcine foreleg. Computed tomography scanning was performed on a 320-row single-source DECT scanner in volume mode with an ascending order of tube currents. Image data sets were reconstructed using FBP and IR with 2 iteration levels (IR1 and IR2). Measurements in regions of interest (ROIs) and volumetric measurements were performed using either fixed parameters for the analysis software (epoxy phantom) or parameters specifically adapted for each data set (porcine phantom). Seven retrospectively identified clinical data sets were used for validation in patients. Rm-ANOVA was used for statistical analysis. No institutional review board approval was required.

RESULTS: We found no differences in Hounsfield units between the different reconstruction algorithms (P = 0.09 and 0.05 for 80 and 135 kVp, respectively) and the calculated dual-energy gradient (P = 0.27). Filtered back projection detected less uric acid compared with IR (with fixed parameters: 6.0 ± 0.3 cm for FBP and 6.1 ± 0.2 for IR1 and IR2; with adapted thresholds: 1.2 ± 0.3 cm for FBP and 1.8 ± 0.1 and 2.0 ± 0.1 for IR1 and IR2, respectively). The differences were significant for all measurements (P = 0.0003). Also in the test cases, FBP detected significantly fewer tophi (mean volume, 1.38 ± 2.1 cm) compared with IR1 (1.86 ± 2.9) and IR2 (2.07 ± 3.1) (P = 0.04).

CONCLUSIONS: Iterative reconstruction has the potential to improve the sensitivity of a DECT scan for gouty tophi, to decrease radiation exposure, or to combine both options.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app