Journal Article
Multicenter Study
Observational Study
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Cardiac cycle efficiency and dicrotic pressure variations: new parameters for fluid therapy: An observational study.

BACKGROUND: During a fluid challenge, the changes in cardiac performance and peripheral circulatory tone are closely related to the position of the ventricle on the Frank-Starling curve. Some patients have a good haemodynamic response to a fluid challenge, others hardly any response. The early haemodynamic effects of a fluid challenge could predict the final response before the entire fluid volume has been administered.

OBJECTIVE: To assess whether a multivariate logistic regression model, including pulse pressure variation (PPV), cardiac cycle efficiency (CCE), arterial elastance and the difference between the dicrotic pressure and both systolic and mean arterial pressure (SAP - Pdic and MAP - Pdic) can predict cardiac responsiveness early during a fluid challenge in comparison with the standard procedure described elsewhere.

DESIGN: Observational study.

SETTING: Elective surgical patients undergoing laparotomy, enrolled in two Italian University Hospitals.

PATIENTS: Fifty adult surgical patients, ventilated with a lung protective strategy, were enrolled and data from 46 were analysed.

INTERVENTIONS: A fluid challenge consisting of 500 ml of crystalloid infused over 10 min.

MAIN OUTCOME MEASURES AND ANALYSIS: The changes in CCE, arterial elastance, SAP - Pdic and MAP - Pdic were compared using analysis of variance. A multivariate logistic regression analysis utilising baseline values and the first minute measuring a variation statistically significant for the considered variables.

RESULTS: At baseline, PPV correctly identified 70% of patients (89% of non-responders; 42% of responders). The model, including baseline PPV, ΔCCE and ΔSAP - Pdic, correctly identified the efficiency of fluid challenge in 87% of patients (84.2% of responders; 92.5 of non-responders) after 5 min from fluid challenge infusion.

CONCLUSION: In this pilot study conducted in a population of surgical patients mechanically ventilated with a VT less than 8 ml kg, a dynamic model of fluid challenge assessment, including PPV, ΔCCE and ΔSAP - Pdic, enhances the prediction of fluid challenge response after 5 min of a 10-min administration.

TRIAL REGISTRATION: ACTRN12616001479493.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app