We have located links that may give you full text access.
Validity and Reliability of Assessing Body Composition Using a Mobile Application.
Medicine and Science in Sports and Exercise 2017 December
PURPOSE: The purpose of this study was to determine the validity and reliability of the LeanScreen (LS) mobile application that estimates percent body fat (%BF) using estimates of circumferences from photographs.
METHODS: The %BF of 148 weight-stable adults was estimated once using dual-energy x-ray absorptiometry (DXA). Each of two administrators assessed the %BF of each subject twice using the LS app and manually measured circumferences. A mixed-model ANOVA and Bland-Altman analyses were used to compare the estimates of %BF obtained from each method. Interrater and intrarater reliabilities values were determined using multiple measurements taken by each of the two administrators.
RESULTS: The LS app and manually measured circumferences significantly underestimated (P < 0.05) the %BF determined using DXA by an average of -3.26 and -4.82 %BF, respectively. The LS app (6.99 %BF) and manually measured circumferences (6.76 %BF) had large limits of agreement. All interrater and intrarater reliability coefficients of estimates of %BF using the LS app and manually measured circumferences exceeded 0.99.
CONCLUSIONS: The estimates of %BF from manually measured circumferences and the LS app were highly reliable. However, these field measures are not currently recommended for the assessment of body composition because of significant bias and large limits of agreements.
METHODS: The %BF of 148 weight-stable adults was estimated once using dual-energy x-ray absorptiometry (DXA). Each of two administrators assessed the %BF of each subject twice using the LS app and manually measured circumferences. A mixed-model ANOVA and Bland-Altman analyses were used to compare the estimates of %BF obtained from each method. Interrater and intrarater reliabilities values were determined using multiple measurements taken by each of the two administrators.
RESULTS: The LS app and manually measured circumferences significantly underestimated (P < 0.05) the %BF determined using DXA by an average of -3.26 and -4.82 %BF, respectively. The LS app (6.99 %BF) and manually measured circumferences (6.76 %BF) had large limits of agreement. All interrater and intrarater reliability coefficients of estimates of %BF using the LS app and manually measured circumferences exceeded 0.99.
CONCLUSIONS: The estimates of %BF from manually measured circumferences and the LS app were highly reliable. However, these field measures are not currently recommended for the assessment of body composition because of significant bias and large limits of agreements.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
The Effect of Albumin Administration in Critically Ill Patients: A Retrospective Single-Center Analysis.Critical Care Medicine 2024 Februrary 8
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app