We have located links that may give you full text access.
A novel method for CT dosimetry with a suspended phantom setup.
Physica Medica : PM 2017 August
PURPOSE: This work presents a method for estimating CT dosimetric indices with a prototype designed for suspending the phantom/ion chamber system fixed at the CT isocenter. The purpose of this study was to validate the proposed methodology, which can be used to provide a direct assessment of dosimetric indices in helical scans.
METHODS: The method is based on a reference setup in which the measuring system for CT dosimetry is in a stationary configuration, i.e. not bound to the CT table, and on a mathematical formalism developed for the proposed reference system. The reliability of the method was demonstrated through a set of experimental measurements. Firstly, dosimetric indices were measured with the new method and compared with the indices obtained with the procedure currently used for CT dosimetry (measuring system bound to the CT table). Secondly, dosimetric indices measured with the new method were compared with those displayed on the CT console.
RESULTS: There is good agreement between the dosimetric indices obtained with the standard setup and those obtained with the suspended phantom setup, within the expected range of errors. The difference between dosimetric indices estimated with the proposed method and those displayed on the CT console is below 2%.
CONCLUSIONS: The method enables CT dosimetry to be performed with the dose detector in a stationary longitudinal position thanks to the newly introduced suspended phantom setup. Using this approach, CT dose can be assessed for high pitch helical scans, acquisitions without complete tube rotation and for cases where dynamic collimation is used.
METHODS: The method is based on a reference setup in which the measuring system for CT dosimetry is in a stationary configuration, i.e. not bound to the CT table, and on a mathematical formalism developed for the proposed reference system. The reliability of the method was demonstrated through a set of experimental measurements. Firstly, dosimetric indices were measured with the new method and compared with the indices obtained with the procedure currently used for CT dosimetry (measuring system bound to the CT table). Secondly, dosimetric indices measured with the new method were compared with those displayed on the CT console.
RESULTS: There is good agreement between the dosimetric indices obtained with the standard setup and those obtained with the suspended phantom setup, within the expected range of errors. The difference between dosimetric indices estimated with the proposed method and those displayed on the CT console is below 2%.
CONCLUSIONS: The method enables CT dosimetry to be performed with the dose detector in a stationary longitudinal position thanks to the newly introduced suspended phantom setup. Using this approach, CT dose can be assessed for high pitch helical scans, acquisitions without complete tube rotation and for cases where dynamic collimation is used.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app