Evaluation of a new packaging process for non-autoclavable endoscopes: results for the first 100 microbiological samples.

BACKGROUND: A new process for packaging endoscopes (SureStore® , Medical Innovations Group) immediately after they exit from washing and disinfection in an automated endoscope reprocessor (AER) allows for endoscopes to be stored for up to 15 days.

AIM: To describe the microbiological quality of samples from gastrointestinal endoscopes following this process.

METHODS: Three-month prospective study using microbiological sampling from a stock of 38 gastrointestinal endoscopes carried out in a French University Hospital. The compliance rate (proportion of samples ≤25 cfu with no pathogenic micro-organisms) and the rate of sterile samples (proportion of germ-free samples) were calculated. We then used multivariate analysis to determine the factors associated with the maintenance of sterility.

FINDINGS: One hundred samples were taken from stored endoscopes: 31 stored for ≤3 days, 34 stored between 3 and 7 days, and 35 after storage between 7 and 15 days. The compliance rate was 98% and the sterile sample rate was 60%. Only the time between leaving the AER and packaging was significantly associated with the sterility of samples (P = 0.02). The probability of having a sterile sample decreased 17-fold when the endoscope was packaged >2 h after leaving the AER (P = 0.04) compared to an endoscope packaged within 1 h after leaving the AER.

CONCLUSION: The SureStore process seems capable of satisfactorily maintaining compliance (98%) of samples taken from endoscopes stored for up to 15 days. The delay in packaging should not exceed 1 h, as the rate of sterile samples decreases thereafter.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app