We have located links that may give you full text access.
Circulating CD89-IgA complex does not predict deterioration of kidney function in Korean patients with IgA nephropathy.
Clinical Chemistry and Laboratory Medicine : CCLM 2017 November 28
BACKGROUND: Soluble CD89 (sCD89)-IgA complex plays a key role in the pathogenesis of IgA nephropathy (IgAN). However, there is a lack of evidence supporting this complex as a good biomarker for disease progression. This study aimed to evaluate the usefulness of sCD89-IgA complex for risk stratification of IgAN.
METHODS: A total of 326 patients with biopsy-proven IgAN were included. sCD89-IgA complex was measured by sandwich-enzyme-linked immunosorbent assay. The study endpoints were a 30% decline in estimated glomerular filtration rate (eGFR).
RESULTS: sCD89-IgA complex levels were inversely and weakly associated with eGFR at the time of biopsy (r=-0.12, p=0.03). However, the significance between the two factors was lost in the multivariate linear regression after adjustment of clinical factors (β=0.35, p=0.75). In a multivariate Cox model, the highest (hazard ratio [HR], 0.75; 95% confidence interval [CI], 0.35-1.61; p=0.45) and middle (HR, 0.93; 95% CI, 0.46-1.89; p=0.84) tertiles of sCD89-IgA complex levels were not associated with an increased risk of developing a 30% decrease in eGFR. Furthermore, the decline rates in eGFR did not differ between groups and C-statistics revealed that the sCD89-IgA complex were not superior to clinical factors in predicting disease progression.
CONCLUSIONS: This study found no association between sCD89-IgA complex levels and disease progression in IgAN. Although sCD89 can contribute to the formation of immune complexes, our findings suggest that the sCD89-IgA level is not a good predictor of adverse outcomes and has limited clinical utility as a biomarker for risk stratification in IgAN.
METHODS: A total of 326 patients with biopsy-proven IgAN were included. sCD89-IgA complex was measured by sandwich-enzyme-linked immunosorbent assay. The study endpoints were a 30% decline in estimated glomerular filtration rate (eGFR).
RESULTS: sCD89-IgA complex levels were inversely and weakly associated with eGFR at the time of biopsy (r=-0.12, p=0.03). However, the significance between the two factors was lost in the multivariate linear regression after adjustment of clinical factors (β=0.35, p=0.75). In a multivariate Cox model, the highest (hazard ratio [HR], 0.75; 95% confidence interval [CI], 0.35-1.61; p=0.45) and middle (HR, 0.93; 95% CI, 0.46-1.89; p=0.84) tertiles of sCD89-IgA complex levels were not associated with an increased risk of developing a 30% decrease in eGFR. Furthermore, the decline rates in eGFR did not differ between groups and C-statistics revealed that the sCD89-IgA complex were not superior to clinical factors in predicting disease progression.
CONCLUSIONS: This study found no association between sCD89-IgA complex levels and disease progression in IgAN. Although sCD89 can contribute to the formation of immune complexes, our findings suggest that the sCD89-IgA level is not a good predictor of adverse outcomes and has limited clinical utility as a biomarker for risk stratification in IgAN.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app