Journal Article
Observational Study
Add like
Add dislike
Add to saved papers

Fluid Responsiveness After CArdiac Surgery (FRACAS): A Prospective Observational Study Using Peripheral Near-Infrared Spectroscopy.

OBJECTIVES: To describe tissue oxygen saturation (StO2 ) in response to a vascular occlusion test using thenar eminence and forearm near-infrared spectroscopy (NIRS) and the association with volume responsiveness after cardiac surgery.

DESIGN: Single-center, prospective, observational cohort study.

SETTING: Cardiothoracic intensive care unit.

PARTICIPANTS: Seventy-six post-cardiac surgical adults.

INTERVENTIONS: Immediately before and 10 minutes after a 250-to-500 mL fluid bolus, StO2 was measured in response to a vascular occlusion test to calculate tissue deoxygenation (Rdes ) and reoxygenation (Rres ) rates. Concurrently, systemic hemodynamic, metabolic, and blood gas variables were collected.

MEASUREMENTS AND MAIN RESULTS: A total of 203 boluses were captured using thenar NIRS and 141 boluses using forearm NIRS. Approximately 25% of boluses increased cardiac output by ≥15% (volume responders). Thenar and forearm Rdes decreased in responders, but increased (thenar) or remained unchanged (forearm) in nonresponders. A logistic regression model of the association among StO2 , Rdes and Rres , and volume responsiveness was significant for thenar measurements (p = 0.001) with an area under the receiver operating characteristic of 0.69 (95% confidence interval: 0.62-0.75). It also was significant (p = 0.02) for forearm measurements, with an area under the receiver operating characteristic of 0.71 (0.62-0.79). Rdes was an independent variable in both instances (odds ratio 0.31 [0.14-0.69], thenar; odds ratio 0.60 [0.45-0.80], forearm). Thenar and forearm NIRS variables were correlated poorly with cardiac output, stroke volume, systemic oxygen delivery and consumption index, mixed venous, and central venous oxygen saturation (Spearman׳s coefficients, r = 0.17-0.46, p < 0.002).

CONCLUSION: In post-cardiac surgical patients, thenar and forearm NIRS variables were associated with volume responsiveness although not achieving precision necessary for clinical management.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app