Computer assisted total knee arthroplasty: a real navigation to better results?
Acta Bio-medica : Atenei Parmensis 2017 June 8
BACKGROUND AND AIM OF THE WORK: Computer assisted surgery in knee replacement is still in discussion, but majority of papers affirm an increase of the accuracy in alignment. Aim of our study is to evaluate the accuracy of mechanical axis, the posterior tibial slope and the femoral component rotation with navigation, x-ray and CT data.
METHODS: We have analysed 145 patients who underwent total knee arthroplasty between January 2012 and December 2014. We have checked each patient at 6, 12 and 24 months of follow-up. During each visit, we did a clinical evaluation checking the ROM and a clinical score (KOOS). At 2 years, we did a CT evaluation and a plain x-ray evaluation.
RESULTS: 125 patients have completed the follow-up. Mean follow-up time was 2,6 years. Both ROM and KOOS values increased during follow-up. About the mechanical axis, both x-ray and CT data showed a mean deviation <2° from the target. About posterior tibial slope and femoral component rotation, CT data showed a mean deviation of <3° from the target. Mean difference between navigation and CT data was <1°.
CONCLUSIONS: According to literature data, our data confirm that computer assisted surgery in knee replacement have a good accuracy of coronal alignment, rotational alignment and posterior tibial slope.
METHODS: We have analysed 145 patients who underwent total knee arthroplasty between January 2012 and December 2014. We have checked each patient at 6, 12 and 24 months of follow-up. During each visit, we did a clinical evaluation checking the ROM and a clinical score (KOOS). At 2 years, we did a CT evaluation and a plain x-ray evaluation.
RESULTS: 125 patients have completed the follow-up. Mean follow-up time was 2,6 years. Both ROM and KOOS values increased during follow-up. About the mechanical axis, both x-ray and CT data showed a mean deviation <2° from the target. About posterior tibial slope and femoral component rotation, CT data showed a mean deviation of <3° from the target. Mean difference between navigation and CT data was <1°.
CONCLUSIONS: According to literature data, our data confirm that computer assisted surgery in knee replacement have a good accuracy of coronal alignment, rotational alignment and posterior tibial slope.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app