Oxygen-Sensing Paint-On Bandage: Calibration of a Novel Approach in Tissue Perfusion Assessment.
Plastic and Reconstructive Surgery 2017 July
BACKGROUND: Knowledge of tissue oxygenation status is fundamental in the prevention of postoperative flap failure. Recently, the authors introduced a novel oxygen-sensing paint-on bandage that incorporated an oxygen-sensing porphyrin with a commercially available liquid bandage matrix. In this study, the authors extend validation of their oxygen-sensing bandage by comparing it to the use of near-infrared tissue oximetry in addition to Clark electrode measurements.
METHODS: The oxygen-sensing paint-on bandage was applied to the left hind limb in a rodent model. Simultaneously, a near-infrared imaging device and Clark electrode were attached to the right and left hind limbs, respectively. Tissue oxygenation was measured under normal, ischemic (aortic ligation), and reperfused conditions.
RESULTS: On average, the oxygen-sensing paint-on bandage measured a decrease in transdermal oxygenation from 85.2 mmHg to 64.1 mmHg upon aortic ligation. The oxygen-sensing dye restored at 81.2 mmHg after unclamping. Responses in both control groups demonstrated a similar trend. Physiologic changes from normal to ischemic and reperfused conditions were statistically significantly different in all three techniques (p < 0.001).
CONCLUSIONS: The authors' newly developed oxygen-sensing paint-on bandage exhibits a comparable trend in oxygenation recordings in a rat model similar to conventional oxygenation assessment techniques. This technique could potentially prove to be a valuable tool in the routine clinical management of flaps following free tissue transfer. Incorporating oxygen-sensing capabilities into a simple wound dressing material has the added benefit of providing both wound protection and constant wound oxygenation assessment.
METHODS: The oxygen-sensing paint-on bandage was applied to the left hind limb in a rodent model. Simultaneously, a near-infrared imaging device and Clark electrode were attached to the right and left hind limbs, respectively. Tissue oxygenation was measured under normal, ischemic (aortic ligation), and reperfused conditions.
RESULTS: On average, the oxygen-sensing paint-on bandage measured a decrease in transdermal oxygenation from 85.2 mmHg to 64.1 mmHg upon aortic ligation. The oxygen-sensing dye restored at 81.2 mmHg after unclamping. Responses in both control groups demonstrated a similar trend. Physiologic changes from normal to ischemic and reperfused conditions were statistically significantly different in all three techniques (p < 0.001).
CONCLUSIONS: The authors' newly developed oxygen-sensing paint-on bandage exhibits a comparable trend in oxygenation recordings in a rat model similar to conventional oxygenation assessment techniques. This technique could potentially prove to be a valuable tool in the routine clinical management of flaps following free tissue transfer. Incorporating oxygen-sensing capabilities into a simple wound dressing material has the added benefit of providing both wound protection and constant wound oxygenation assessment.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app