We have located links that may give you full text access.
Determination of the Heart-to-Mediastinum Ratio of 123 I-MIBG Uptake Using Dual-Isotope ( 123 I-MIBG/ 99m Tc-Tetrofosmin) Multipinhole Cadmium-Zinc-Telluride SPECT in Patients with Heart Failure.
Journal of Nuclear Medicine 2018 Februrary
The aim of this retrospective study was to compare the heart-to-mediastinum ratio (HMR) of 123 I-metaiodobenzylguanidine (123 I-MIBG) uptake obtained using a multipinhole cadmium-zinc-telluride (CZT) camera with that obtained using conventional planar imaging. Methods: Forty consecutive heart failure patients underwent planar acquisition 4 h after 123 I-MIBG injection (191 ± 41 [mean ± SD] MBq). To localize the heart using the CZT camera, 99m Tc-tetrofosmin (358 ± 177 MBq) was administered and dual-isotope acquisition was performed. The HMRs were calculated with conventional planar imaging (HMRplanar ), with anterior reprojection images using the CZT camera (HMRreproj ), and with transaxial reconstructed images using the CZT camera (HMRtransaxial ). In a phantom study, we estimated a linear model fitting the CZT camera data to the planar data, and we applied it to provide corrected CZT camera-determined HMRs in patients (cHMRreproj and cHMRtransaxial ). Results: Thirty-four men and 6 women (71 ± 9 y old) with ischemic (22 patients) and nonischemic (18 patients) heart failure completed the study. For 22 of the 40 patients (55%), the New York Heart Association classification was class II and the ejection fraction was 35% ± 9%. HMRreproj (1.12 ± 0.19) and HMRtransaxial (1.35 ± 0.34) were lower than HMRplanar (1.44 ± 0.14) ( P < 0.0001 and P < 0.01, respectively). cHMRreproj (1.54 ± 0.09) and cHMRtransaxial (1.45 ± 0.14) were significantly different ( P < 0.0001). Lin concordance correlation and Bland-Altman analysis demonstrated an almost perfect concordance and a high agreement between HMRplanar and cHMRtransaxial ( P was not significant) but not between HMRplanar and cHMRreproj ( P < 0.0001). Conclusion: This study demonstrated that determination of the late HMR of cardiac 123 I-MIBG uptake using dual-isotope (123 I and 99m Tc) acquisition on a multipinhole CZT camera was feasible in patients with heart failure. However, this determination should be performed using transaxial reconstructed images and linear correction based on phantom data acquisitions.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app