Clinical application of a novel endoscopic mask: a randomized controlled, multi-center trial in patients undergoing awake fiberoptic bronchoscopic intubation

Tianxiao Zou, Zhenling Huang, Xiaoxue Hu, Guangyu Cai, Miao He, Shanjuan Wang, Ping Huang, Bin Yu
BMC Anesthesiology 2017 June 15, 17 (1): 79
28619016

BACKGROUND: Awake fiberoptic bronchoscopic tracheal intubation is usually regarded as an effective method in the management of predicted difficult airway. Hypoxia during awake nasal fiberoptic bronchoscopic intubation leads to discontinuation of the procedure, prolonged manipulation time and increased risk of severe complications. The main aim of the study was to test whether the novel endoscopic mask is helpful for hypoxia during the intubation.

METHODS: This was a randomized, controlled, multi-center study. 55 patients were recruited, but one patient was lost to follow-up. Finally, 54 patients (19 man and 35 women) were analyzed. After entering the operating room, nasal catheter oxygen-providing was given in the control group, and the treatment group received endoscopic mask oxygen-providing, with a flow rate of 3 L/min, lasting into the end of the intubation. Primary outcomes included mean arterial pressure, heart rate, minimum pulse oxygen saturation and incidence of pulse oxygen saturation ≤ 90%. Secondary outcomes included number of intubation attempts and time to intubation. All outcomes were finally measured.

RESULTS: Minimum pulse oxygen saturation during awake nasal fiberoptic bronchoscopic tracheal intubation was significantly higher in the endoscopic mask intubation group (91.7% ± 4.7%) than that the nasal catheter intubation group (87.6% ± 8.2%, P = 0.031. Furthermore, the incidence of pulse oxygen saturation ≤ 90% was significantly lower in the endoscopic mask intubation group (20.0%, 5/25) than that in the nasal catheter intubation group (51.7%, 15/29, P = 0.037). But mean arterial pressure of during intubation was significantly higher in the endoscopic mask group (100.0 ± 13.3 vs 90.3 ± 21.8, P = 0.049). In addition, there were no differences in the number of intubation attempts (P = 0.45) or time to intubation between the two groups (P = 0.38).

CONCLUSIONS: The endoscopic mask was safely used in awake fiberoptic bronchoscopic tracheal intubation, with advantages of stable blood pressure and potential prevention of desaturation. Beginners for the intubation procedure and patients at high risk of hypoxia could benefit from the use of the endoscopic mask.

TRIAL REGISTRATION: Trial registration: www.chictr.org.cn . Registration No.: ChiCTR-TRC-13004086. Date of Registration: 8th, Sep, 2013.

Comments

You need to log in or sign up for an account to be able to comment.

No comments yet, be the first to post one!

Related Papers

Available on the App Store

Available on the Play Store

Read Institutional Edition
Remove bar
Read by QxMD icon Read
28619016
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"