We have located links that may give you full text access.
Noninvasive pulmonary transit time: A new parameter for general cardiac performance.
Echocardiography 2017 August
INTRODUCTION: Pulmonary transit time (PTT) assessed with contrast-enhanced ultrasound (CEUS) is a novel tool to evaluate cardiac function. PTT represents the time for a bolus of contrast to pass from the right to the left ventricle, measured according to the indicator dilution principles using CEUS. We investigated the hypothesis that PTT is a measure of general cardiac performance in patient populations eligible for cardiac resynchronization therapy (CRT).
METHODS: The study population consisted of heart failure patients referred for CRT with NYHA class II-IV, left ventricular ejection fraction (LVEF)≤35% and QRS≥120 ms. CEUS, ECG, and blood were analyzed, and participants completed a quality of life questionnaire at baseline and 3 months after CRT implantation. Normalized PTT (nPTT) was calculated to compensate for the heart rate. Correlations were assessed with Pearson's or Spearman's coefficients and stratified for rhythm and NYHA class.
RESULTS: The study population consisted of 94 patients (67 men) with a mean age of 70±8.9 years. (n)PTT was significantly correlated with left ventricular parameters (rs =-.487, P<.001), right ventricular parameters (r=-.282, P=.004), N-terminal pro-B-type natriuretic peptide (NT-proBNP) (rs =.475, P<.001), and quality of life (rs =.364, P<.001). Stronger significant correlations were found in patients in sinus rhythm.
CONCLUSION: CEUS-derived PTT and nPTT correlate to a fair degree with measures of systolic and diastolic function, NT-pro-BNP, and quality of life. As CEUS-derived PTT can be obtained easily, noninvasively and at the bedside, it is a promising future measure of general cardiac performance.
METHODS: The study population consisted of heart failure patients referred for CRT with NYHA class II-IV, left ventricular ejection fraction (LVEF)≤35% and QRS≥120 ms. CEUS, ECG, and blood were analyzed, and participants completed a quality of life questionnaire at baseline and 3 months after CRT implantation. Normalized PTT (nPTT) was calculated to compensate for the heart rate. Correlations were assessed with Pearson's or Spearman's coefficients and stratified for rhythm and NYHA class.
RESULTS: The study population consisted of 94 patients (67 men) with a mean age of 70±8.9 years. (n)PTT was significantly correlated with left ventricular parameters (rs =-.487, P<.001), right ventricular parameters (r=-.282, P=.004), N-terminal pro-B-type natriuretic peptide (NT-proBNP) (rs =.475, P<.001), and quality of life (rs =.364, P<.001). Stronger significant correlations were found in patients in sinus rhythm.
CONCLUSION: CEUS-derived PTT and nPTT correlate to a fair degree with measures of systolic and diastolic function, NT-pro-BNP, and quality of life. As CEUS-derived PTT can be obtained easily, noninvasively and at the bedside, it is a promising future measure of general cardiac performance.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app