We have located links that may give you full text access.
Diagnostic value and relative weight of sequence-specific magnetic resonance features in characterizing clinically significant prostate cancers.
PloS One 2017
PURPOSE: To assess the diagnostic weight of sequence-specific magnetic resonance features in characterizing clinically significant prostate cancers (csPCa).
MATERIALS AND METHODS: We used a prospective database of 262 patients who underwent T2-weighted, diffusion-weighted, and dynamic contrast-enhanced (DCE) imaging before prostatectomy. For each lesion, two independent readers (R1, R2) prospectively defined nine features: shape, volume (V_Max), signal abnormality on each pulse sequence, number of pulse sequences with a marked (S_Max) and non-visible (S_Min) abnormality, likelihood of extracapsular extension (ECE) and PSA density (dPSA). Overall likelihood of malignancy was assessed using a 5-level Likert score. Features were evaluated using the area under the receiver operating characteristic curve (AUC). csPCa was defined as Gleason ≥7 cancer (csPCa-A), Gleason ≥7(4+3) cancer (csPCa-B) or Gleason ≥7 cancer with histological extraprostatic extension (csPCa-C).
RESULTS: For csPCa-A, the Signal1 model (S_Max+S_Min) provided the best combination of signal-related variables, for both readers. The performance was improved by adding V_Max, ECE and/or dPSA, but not shape. All models performed better with DCE findings than without. When moving from csPCa-A to csPCa-B and csPCa-C definitions, the added value of V_Max, dPSA and ECE increased as compared to signal-related variables, and the added value of DCE decreased. For R1, the best models were Signal1+ECE+dPSA (AUC = 0,805 [95%CI:0,757-0,866]), Signal1+V_Max+dPSA (AUC = 0.823 [95%CI:0.760-0.893]) and Signal1+ECE+dPSA [AUC = 0.840 (95%CI:0.774-0.907)] for csPCa-A, csPCA-B and csPCA-C respectively. The AUCs of the corresponding Likert scores were 0.844 [95%CI:0.806-0.877, p = 0.11], 0.841 [95%CI:0.799-0.876, p = 0.52]) and 0.849 [95%CI:0.811-0.884, p = 0.49], respectively. For R2, the best models were Signal1+V_Max+dPSA (AUC = 0,790 [95%CI:0,731-0,857]), Signal1+V_Max (AUC = 0.813 [95%CI:0.746-0.882]) and Signal1+ECE+V_Max (AUC = 0.843 [95%CI: 0.781-0.907]) for csPCa-A, csPCA-B and csPCA-C respectively. The AUCs of the corresponding Likert scores were 0. 829 [95%CI:0.791-0.868, p = 0.13], 0.790 [95%CI:0.742-0.841, p = 0.12]) and 0.808 [95%CI:0.764-0.845, p = 0.006]), respectively.
CONCLUSION: Combination of simple variables can match the Likert score's results. The optimal combination depends on the definition of csPCa.
MATERIALS AND METHODS: We used a prospective database of 262 patients who underwent T2-weighted, diffusion-weighted, and dynamic contrast-enhanced (DCE) imaging before prostatectomy. For each lesion, two independent readers (R1, R2) prospectively defined nine features: shape, volume (V_Max), signal abnormality on each pulse sequence, number of pulse sequences with a marked (S_Max) and non-visible (S_Min) abnormality, likelihood of extracapsular extension (ECE) and PSA density (dPSA). Overall likelihood of malignancy was assessed using a 5-level Likert score. Features were evaluated using the area under the receiver operating characteristic curve (AUC). csPCa was defined as Gleason ≥7 cancer (csPCa-A), Gleason ≥7(4+3) cancer (csPCa-B) or Gleason ≥7 cancer with histological extraprostatic extension (csPCa-C).
RESULTS: For csPCa-A, the Signal1 model (S_Max+S_Min) provided the best combination of signal-related variables, for both readers. The performance was improved by adding V_Max, ECE and/or dPSA, but not shape. All models performed better with DCE findings than without. When moving from csPCa-A to csPCa-B and csPCa-C definitions, the added value of V_Max, dPSA and ECE increased as compared to signal-related variables, and the added value of DCE decreased. For R1, the best models were Signal1+ECE+dPSA (AUC = 0,805 [95%CI:0,757-0,866]), Signal1+V_Max+dPSA (AUC = 0.823 [95%CI:0.760-0.893]) and Signal1+ECE+dPSA [AUC = 0.840 (95%CI:0.774-0.907)] for csPCa-A, csPCA-B and csPCA-C respectively. The AUCs of the corresponding Likert scores were 0.844 [95%CI:0.806-0.877, p = 0.11], 0.841 [95%CI:0.799-0.876, p = 0.52]) and 0.849 [95%CI:0.811-0.884, p = 0.49], respectively. For R2, the best models were Signal1+V_Max+dPSA (AUC = 0,790 [95%CI:0,731-0,857]), Signal1+V_Max (AUC = 0.813 [95%CI:0.746-0.882]) and Signal1+ECE+V_Max (AUC = 0.843 [95%CI: 0.781-0.907]) for csPCa-A, csPCA-B and csPCA-C respectively. The AUCs of the corresponding Likert scores were 0. 829 [95%CI:0.791-0.868, p = 0.13], 0.790 [95%CI:0.742-0.841, p = 0.12]) and 0.808 [95%CI:0.764-0.845, p = 0.006]), respectively.
CONCLUSION: Combination of simple variables can match the Likert score's results. The optimal combination depends on the definition of csPCa.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app