Cardiac Output Measurements Based on the Pulse Wave Transit Time and Thoracic Impedance Exhibit Limited Agreement With Thermodilution Method During Orthotopic Liver Transplantation.

BACKGROUND: Orthotopic liver transplantation (OLT) is characterized by significant intraoperative hemodynamic variability. Accurate and real-time cardiac output (CO) monitoring aids clinical decision making during OLT. The purpose of this study is to compare accuracy, precision, and trending ability of CO estimation obtained noninvasively using pulse wave transit time (estimated continuous cardiac output [esCCO; Nihon Kohden, Tokyo, Japan]) or thoracic bioimpedance (ICON; Osypka Medical GmbH, Berlin, Germany) to thermodilution cardiac output (TDCO) measured with a pulmonary artery catheter.

METHODS: Nineteen patients undergoing OLT were enrolled. CO measurements were collected with esCCO, ICON, and thermodilution at 5 time points: (T1) pulmonary artery catheter insertion; (T2) surgical incision; (T3) portal reperfusion; (T4) hepatic arterial reperfusion; and (T5) abdominal closure. The results were analyzed with Bland-Altman plot, percentage error (the percentage of the difference between the CO estimated with the noninvasive monitoring device and CO measured with the thermodilution technique), 4-quadrant plot with concordance rate (the percentage of the total number of points in the I and III quadrant of the 4-quadrant plot), and concordance correlation coefficient (a measure of how well the pairs of observations deviate from the 45-degree line of perfect agreement).

RESULTS: Although TDCO increased at T3-T5, both esCCO and ICON failed to track the changes of CO with sufficient accuracy and precision. The mean bias of esCCO and ICON compared to TDCO were -2.0 L/min (SD, ±2.7 L/min) and -3.3 L/min (SD, ±2.8 L/min), respectively. The percentage error was 69% for esCCO and 77% for ICON. The concordance correlation coefficient was 0.653 (95% confidence interval [CI], 0.283-0.853) for esCCO and 0.310 (95% CI, -0.167 to 0.669) for ICON. Nonetheless, esCCO and ICON exhibited reasonable trending ability of TDCO (concordance rate: 95% [95% CI, 88-100] and 100% [95% CI, 93-100]), respectively. The mean bias was correlated with systemic vascular resistance (SVR) and arterial elastance (Ea) for esCCO (SVR, r = 0.610, 95% CI, 0.216-0.833, P < .0001; Ea, r = 0.692, 95% CI, 0.347-0.872; P < .0001) and ICON (SVR, r = 0.573, 95% CI, 0.161-0.815, P < .0001; Ea, r = 0.612, 95% CI, 0.219-0.834, P < .0001).

CONCLUSIONS: The noninvasive CO estimation with esCCO and ICON exhibited limited accuracy and precision, despite with reasonable trending ability, when compared to TDCO, during OLT. The inaccuracy of esCCO and ICON is especially large when SVR and Ea were decreased during the neohepatic phase. Further refinement of the technology is desirable before noninvasive techniques can replace TDCO during OLT.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app