We have located links that may give you full text access.
Agreement analysis comparing iPad LCVA and Sloan testing in multiple sclerosis patients.
BACKGROUND: Visual symptoms are common in multiple sclerosis (MS). Low-contrast visual acuity (LCVA) testing using Sloan charts has demonstrated increased sensitivity for visual deficits compared to high-contrast acuity testing. Computerized testing of visual acuity may facilitate use in the clinic setting.
OBJECTIVES: To evaluate the agreement between an iPad-based and Sloan testing of LCVA in a cohort of MS patients.
METHODS: A total of 38 patients with relapsing-remitting MS were enrolled after providing informed written consent at Partners MS Center, Brigham and Women's hospital. Monocular LCVA was measured using retroilluminated Sloan chart and iPad-based LogMAR chart. Number of correct letters and agreement between two measurements were assessed for each eye using Bland-Altman analysis and paired t-test.
RESULTS: For both eyes, there was no significant difference in number correct between the two measurements using a paired t-test, and there was high correlation between two measurements (oculus dextrus (OD) r = 0.89, p < 0.001; oculus sinister (OS) r = 0.78, p < 0.001). The limits of agreement were -7.9 to +8.5 letters for the right eye and -10.9 to +11.2 letters for the left eye.
CONCLUSION: An iPad-based LCVA test shows good agreement with Sloan testing in MS patients.
OBJECTIVES: To evaluate the agreement between an iPad-based and Sloan testing of LCVA in a cohort of MS patients.
METHODS: A total of 38 patients with relapsing-remitting MS were enrolled after providing informed written consent at Partners MS Center, Brigham and Women's hospital. Monocular LCVA was measured using retroilluminated Sloan chart and iPad-based LogMAR chart. Number of correct letters and agreement between two measurements were assessed for each eye using Bland-Altman analysis and paired t-test.
RESULTS: For both eyes, there was no significant difference in number correct between the two measurements using a paired t-test, and there was high correlation between two measurements (oculus dextrus (OD) r = 0.89, p < 0.001; oculus sinister (OS) r = 0.78, p < 0.001). The limits of agreement were -7.9 to +8.5 letters for the right eye and -10.9 to +11.2 letters for the left eye.
CONCLUSION: An iPad-based LCVA test shows good agreement with Sloan testing in MS patients.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app