We have located links that may give you full text access.
The Use of Dual Reconstruction Plates for Failed Fixation of Patellar Fracture after Total Knee Replacement: A Case Report.
Malaysian Orthopaedic Journal 2016 November
Patellar fracture after total knee replacement (TKR) is one of the challenging problems in periprosthetic fracture. Open reduction with internal fixation (ORIF), as tension band wiring (TBW), usually required in cases with extensor mechanism disruption. However, many studies reported a high failure rate after using this technique. In this report, we presented an interesting case of periprosthetic patellar fracture after TKR with TBW failure that was successfully treated with double non-locking reconstruction plates fixation and TBW augmentation.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app