Characterization of a new candidate isotopic reference material for natural Pb using primary measurement method.

A lead isotopic standard solution with natural abundance has been developed by applying a mixture of a solution of enriched208 Pb and a solution of enriched204 Pb (208 Pb-204 Pb double spike solution) as bracketing method. The amount-of-substance ratio of208 Pb:204 Pb in this solution is accurately measured by applying EDTA titrimetry, which is one of the primary measurement methods, to each enriched Pb isotope solution. Also metal impurities affecting EDTA titration and minor lead isotopes contained in each enriched Pb isotope solution are quantified by ICP-SF-MS. The amount-of-substance ratio of208 Pb:204 Pb in the208 Pb-204 Pb double spike solution is 0.961959 ± 0.000056 (combined standard uncertainty; k = 1). Both the measurement of lead isotope ratios in a candidate isotopic standard solution and the correction of mass discrimination in MC-ICP-MS are carried out by coupling of a bracketing method with the208 Pb-204 Pb double spike solution and a thallium internal addition method, where thallium solution is added to the standard and the sample. The measured lead isotope ratios and their expanded uncertainties (k = 2) in the candidate isotopic standard solution are 18.0900 ± 0.0046 for206 Pb:204 Pb, 15.6278 ± 0.0036 for207 Pb:204 Pb, 38.0626 ± 0.0089 for208 Pb:204 Pb, 2.104406 ± 0.00013 for208 Pb:206 Pb, and 0.863888 ± 0.000036 for207 Pb:206 Pb. The expanded uncertainties are about one half of the stated uncertainty for NIST SRM 981, for208 Pb:204 Pb,207 Pb:204 Pb and206 Pb:204 Pb, or one eighth, for208 Pb:206 Pb and207 Pb:206 Pb, The combined uncertainty consists of the uncertainties due to lead isotope ratio measurements and the remaining time-drift effect of mass discrimination in MC-ICP-MS, which is not removed by the coupled correction method. In the measurement of208 Pb:204 Pb,207 Pb:204 Pb and206 Pb:204 Pb, the latter contribution is two or three times larger than the former. When the coupling of a bracketing method with the208 Pb-204 Pb double spike solution and a thallium internal addition method is applied to the analysis of NIST SRM 981, the measured lead isotope ratios are in good agreement with its certified values. This proves that the developed method is not only consistent with the conventional one by NIST SRM 981 but also enables measurement of the lead isotope ratios with higher precision.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app