Add like
Add dislike
Add to saved papers

Management of Risks From Water and Ice From Ice Machines for the Very Immunocompromised Host: A Process Improvement Project Prompted by an Outbreak of Rapidly Growing Mycobacteria on a Pediatric Hematopoietic Stem Cell Transplant (Hsct) Unit.

BACKGROUND In 2011, pediatric hematopoietic stem cell transplant (HSCT) patients were moved from an older hospital to a new children's hospital. To minimize bacterial growth in the new hospital's water during construction, the plumbing system was flushed and disinfected before occupancy. However, 6 months after occupancy, an increased incidence of rapidly growing mycobacteria (RGM) was detected in clinical cultures. Over 10 months, 15 pediatric HSCT patients were infected, while no pediatric HSCT patients had been infected in the preceding 12 months. OBJECTIVE To determine the cause of the outbreak and to interrupt patient acquisition of RGM. METHODS Water samples were collected from water entering the hospital and from drinking water and ice machines (DWIMs) from the old and new hospitals. Total heterotrophic plate counts (HPCs, CFU/mL) of water were undertaken, and select isolates were identified as RGM. RESULTS The cause of the outbreak was increased bacterial levels in the water (including RGM) in the DWIMs in the new (2011) hospital. Tests revealed higher HPCs in drinking water and ice from the DWIMs in the new hospital than in the DWIMs in the old hospital. Ultimately, HPCs were reduced by several different interventions. CONCLUSION In response to an RGM outbreak, HSCT patients were banned from ingesting DWIM ice and water and bottled water was provided. Since this interverntion 4 years ago, no additional RGM isolates have been identified in HSCT patient cultures. Our measures to reduce HPCs to goal levels in drinking water from DWIMs were successful, but the HPCs for ice have not consistently reached the goal of <500 CFU/mL. Infect Control Hosp Epidemiol 2017;38:792-800.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app