Course of serum amyloid A (SAA) plasma concentrations in horses undergoing surgery for injuries penetrating synovial structures, an observational clinical study.

BACKGROUND: Injuries penetrating synovial structures are common in equine practice and often result in septic synovitis. Significantly increased plasma levels of serum amyloid A (SAA) have been found in various infectious conditions in horses including wounds and septic arthritis. Plasma SAA levels were found to decrease rapidly once the infectious stimulus was eliminated. The purpose of the current study was to investigate the usefulness of serial measurements of plasma SAA as a monitoring tool for the response to treatment of horses presented with injuries penetrating synovial structures. In the current study plasma SAA concentrations were measured every 48 hours (h) during the course of treatment.

RESULTS: A total of 19 horses with a wound penetrating a synovial structure were included in the current study. Horses in Group 1 (n = 12) (injuries older than 24 h) only needed one surgical intervention. Patients in this group had significantly lower median plasma SAA levels (P = 0.001) between 48 h (median 776 mg/L) and 96 h (median 202 mg/L) after surgery. A significant decrease (P = 0.004) in plasma SAA levels was also observed between 96 h after surgery (median 270 mg/L) and 6 days (d) after surgery (median 3 mg/L). Four horses (Group 2) required more than one surgical intervention. In contrast to Group 1 patients in Group 2 had either very high initial plasma concentrations (3378 mg/L), an increase or persistently high concentrations of plasma SAA after the first surgery (median 2525 mg/L). A small group of patients (n = 3) (Group 3) were admitted less than 24 h after sustaining a wound. In this group low SAA values at admission (median 23 mg/L) and peak concentrations at 48 h after surgery (median 1016 mg/L) were observed followed by a decrease in plasma SAA concentration over time.

CONCLUSIONS: A decrease in plasma SAA concentrations between two consecutive time points could be associated with positive response to treatment in the current study. Therefore, serial measurements of plasma SAA could potentially be used as an additional inexpensive, quick and easy tool for monitoring the treatment response in otherwise healthy horses presented with injuries penetrating synovial structures. However further studies will be necessary to ascertain its clinical utility.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app