Embolization for persistent type IA endoleaks after chimney endovascular aneurysm repair with Onyx ® .
Diagnostic and Interventional Imaging 2017 December
PURPOSE: The purpose of this study was to determine retrospectively the safety and technical success rate of embolization using ethylene vinyl alcohol copolymer (Onyx® ) for persistent type 1A endoleaks after chimney endovascular aneurysm repair (EVAR) for complex aortic aneurysms.
MATERIAL AND METHODS: Nine consecutive patients (6 men, 3 women) with a mean age of 78.6 years (range: 62-87 years) presenting with persistent type IA endoleaks after chimney EVAR and an increase of aneurysm size were treated using transarterial embolization with Onyx® .
RESULTS: Technical success was obtained in all patients (100%) and no complications were observed. Mean follow-up was 16 months (range: 3-35 months). Primary clinical efficacy was obtained for 8/9 patients (89%) and primary technical efficacy for 6/9 patients (67%). Secondary clinical efficacy was 100%, and secondary technical efficacy was 78%.
CONCLUSION: Our results suggest that arterial embolization using Onyx® appears as a feasible and safe endovascular procedure of type IA endoleaks after chimney EVAR, although further validation is now required.
MATERIAL AND METHODS: Nine consecutive patients (6 men, 3 women) with a mean age of 78.6 years (range: 62-87 years) presenting with persistent type IA endoleaks after chimney EVAR and an increase of aneurysm size were treated using transarterial embolization with Onyx® .
RESULTS: Technical success was obtained in all patients (100%) and no complications were observed. Mean follow-up was 16 months (range: 3-35 months). Primary clinical efficacy was obtained for 8/9 patients (89%) and primary technical efficacy for 6/9 patients (67%). Secondary clinical efficacy was 100%, and secondary technical efficacy was 78%.
CONCLUSION: Our results suggest that arterial embolization using Onyx® appears as a feasible and safe endovascular procedure of type IA endoleaks after chimney EVAR, although further validation is now required.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app