Are Urine Cultures Necessary Prior to Urologic Prosthetic Surgery?
Sexual Medicine Reviews 2018 January
INTRODUCTION: A preoperative negative urine culture is generally advised before implantation of urologic prosthetics to prevent device infection. However, a review of the medical literature indicates sparse evidence to support this practice.
AIM: To describe outcomes for patients undergoing prosthetic implantation without preoperative urine cultures.
METHODS: The cases of men undergoing artificial urinary sphincter (AUS) and/or inflatable penile prosthesis (IPP) placement at a tertiary care center from 2007 through 2015 were reviewed. Of 713 devices implanted in 681 patients (337 AUSs in 314 patients, 376 IPPs in 367), 259 cases without preoperative urine cultures were analyzed (41%). Patients received standard perioperative antibiotics.
MAIN OUTCOME MEASURES: Device infection was diagnosed clinically. Average follow-up was 15 months.
RESULTS: Device infection occurred in 4 of 259 patients (1.5%) with no difference noted in infection rate between device groups (AUS = 3 of 174 [2%]; IPP = 1 of 85 [1%]; P = .99); this rate appears to be consistent with the infection rate of numerous other published prosthetic series. Common skin organisms were implicated as the infectious agents in half the infected devices. Only one patient (0.4%) developed an Escherichia coli infection.
CONCLUSION: This study suggests that prosthetic urologic surgery can be safely performed without preoperative urine cultures. Kavoussi NL, Viers BR, Pagilara TL, et al. Are Urine Cultures Necessary Prior to Urologic Prosthetic Surgery? Sex Med Rev 2018;6:157-161.
AIM: To describe outcomes for patients undergoing prosthetic implantation without preoperative urine cultures.
METHODS: The cases of men undergoing artificial urinary sphincter (AUS) and/or inflatable penile prosthesis (IPP) placement at a tertiary care center from 2007 through 2015 were reviewed. Of 713 devices implanted in 681 patients (337 AUSs in 314 patients, 376 IPPs in 367), 259 cases without preoperative urine cultures were analyzed (41%). Patients received standard perioperative antibiotics.
MAIN OUTCOME MEASURES: Device infection was diagnosed clinically. Average follow-up was 15 months.
RESULTS: Device infection occurred in 4 of 259 patients (1.5%) with no difference noted in infection rate between device groups (AUS = 3 of 174 [2%]; IPP = 1 of 85 [1%]; P = .99); this rate appears to be consistent with the infection rate of numerous other published prosthetic series. Common skin organisms were implicated as the infectious agents in half the infected devices. Only one patient (0.4%) developed an Escherichia coli infection.
CONCLUSION: This study suggests that prosthetic urologic surgery can be safely performed without preoperative urine cultures. Kavoussi NL, Viers BR, Pagilara TL, et al. Are Urine Cultures Necessary Prior to Urologic Prosthetic Surgery? Sex Med Rev 2018;6:157-161.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app