Short communication: Repeatability of β-hydroxybutyrate measurements in capillary blood obtained from the external vulvar skin.

The primary objective of this study was to evaluate the repeatability of measurements of β-hydroxybutyrate (BHB) concentrations in capillary blood obtained from minimal-invasive puncturing of different sites at the external vulva skin of dairy cows. A total of 240 multiparous cows sampled once within 21 d in milk were enrolled in the study. Capillary blood samples were obtained from the right and left labium of the external vulva skin and additionally from a site close to the first puncture. Samples were analyzed by using an electronic hand-held device [FreeStyle Precison Neo (FSP-Neo), Abbott GmbH & Co., Wiesbaden, Germany)]. Additionally, samples from a coccygeal vessel were analyzed as reference in a laboratory. Mean deviations (± standard deviation) between the 3 capillary sampling sites ranged from 0.01 ± 0.14 (left vs. right labium) to 0.02 ± 0.13 mmol/L (left or right labium vs. additional site). The BHB concentrations in capillary blood compared with the reference showed a mean deviation of 0.14 ± 0.18 mmol/L. The Spearman correlation coefficient between BHB concentrations in capillary blood and coccygeal blood was 85.4%. Mixed model analyses showed no significant effect of sampling site or squeezing the skin during sampling procedures on the differences toward the reference. Based on laboratory BHB concentrations of ≥1.2 and ≥1.4 mmol/L, respectively, the prevalence of hyperketonemia was 10.4 (n = 25) and 5.0% (n = 12). Thresholds to detect hyperketonemia with the FSP-Neo were optimized by receiver operating characteristic analyses. Based on a laboratory BHB concentration of ≥1.2 mmol/L thresholds were determined as 1.1 (left labium, 2nd puncture) and 1.0 mmol/L (right labium), with sensitivities between 94 and 99% and specificities between 89 and 97%. Based on a serum BHB concentration of 1.4 mmol/L, receiver operating characteristic analyses resulted in optimized cutoffs of 1.4 mmol/L for all sampling sites at the vulva, with sensitivities of 100% and specificities between 96 and 99%. In conclusion, vulvar capillary blood is suitable for accurate measuring of BHB concentrations by using the FSP-Neo. After adjusting the thresholds, the FSP-Neo provides very good test characteristics independent of the capillary sampling site or squeezing the skin and allows a practical and reliable screening tool for dairy cows.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app