Assuring Consistent Performance of an Insulin-Like Growth Factor 1 MALDImmunoassay by Monitoring Measurement Quality Indicators.

Analytical methods based on mass spectrometry (MS) have been successfully applied in biomarker discovery studies, while the role of MS in translating biomarker candidates to clinical diagnostics is less pronounced. MALDImmunoassays-methods that combine immunoaffinity enrichment with matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometric detection-are attractive analytical approaches for large-scale sample analysis by virtue of their ease of operation and high-throughput capabilities. Despite this fact, MALDImmunoassays are not widely used in clinical diagnostics, which is mainly due to the limited availability of internal standards that can adequately correct for variability in sample preparation and the MALDI process itself. Here we present a novel MALDImmunoassay for quantification of insulin-like growth factor 1 (IGF1) in human plasma. Reliable IGF1 quantification in the range of 10-1000 ng/mL was achieved by employing (15)N-IGF1 as internal standard, which proved to be an essential feature of the IGF1 MALDImmunoassay. The method was validated according to U.S. Food and Drug Administration (FDA) guidelines, which included demonstrating the effectiveness of IGF1/IGF binding protein (IGF1/IGFBP) complex dissociation using sodium dodecyl sulfate (SDS). Furthermore, the MALDImmunoassay compared well with the IDS-iSYS IGF1 immunoassay with high correlation (R(2) = 0.99), although substantially lower levels were reported by the MALDImmunoassay. The method was tested on >1000 samples from a cohort of renal transplant recipients to assess its performance in a clinical setting. On the basis of this study, we identified readouts to monitor the quality of the measurements. Our work shows that MALDI-TOF mass spectrometry is suitable for quantitative biomarker analysis provided that an appropriate internal standard is used and that readouts are monitored to assess the quality of the measurements.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app