Macro-Raman spectroscopy for bulk composition and homogeneity analysis of multi-component pharmaceutical powders.

A new macro-Raman system equipped with a motorized translational sample stage and low-frequency shift capabilities was developed for bulk composition and homogeneity analysis of multi-component pharmaceutical powders. Different sampling methods including single spot and scanning measurement were compared. It was found that increasing sample volumes significantly improved the precision of quantitative composition analysis, especially for poorly mixed powders. The multi-pass cavity of the macro-Raman system increased effective sample volumes by 20 times from the sample volume defined by the collection optics, i.e., from 0.02μL to about 0.4μL. A stochastic model simulating the random sampling process of polydisperse microparticles was used to predict the sampling errors for a specific sample volume. Comparison of fluticasone propionate mass fractions of the commercial products Flixotide® 250 and Seretide® 500 simulated for different sampling volumes with experimentally measured compositions verified that the effective sample volume of a single point macro-Raman measurement in the multi-pass cavity of this instrument was between 0.3μL and 0.5μL. The macro-Raman system was also successfully used for blend uniformity analysis. It was concluded that demixing occurred in the binary mixture of l-leucine and d-mannitol from the observation that the sampling errors indicated by the standard deviations of measured leucine mass fractions increased during mixing, and the standard deviation values were all larger than the theoretical lower limit determined by the simulation. Since sample volume was shown to have a significant impact on measured homogeneity characteristics, it was concluded that powder homogeneity analysis results, i.e., the mean of individual test results and absolute and relative standard deviations, must be presented together with the effective sample volumes of the applied testing techniques for any measurement of powder homogeneity to be fully meaningful.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app