We have located links that may give you full text access.
Comparative Study
Journal Article
Immunosuppressive drugs in whole blood: validation of a commercially available liquid chromatography/tandem mass spectrometry kit and comparison with immunochemical assays.
Rapid Communications in Mass Spectrometry : RCM 2017 July 16
RATIONALE: In the determination of immunosuppressive drugs cyclosporine A (CSA), tacrolimus (TARO), sirolimus (SIRO), and everolimus (EVE) in whole blood there is an open debate about which is the best assay between immunochemistry and liquid chromatography/tandem mass spectrometry (LC/MS/MS). This work is aimed to explore this topic, focusing on the use of updated assays and the analysis of a large number of samples.
METHODS: A certified in vitro diagnostic kit coupled with a medical device LC/MS/MS was validated and applied to the analysis of 1192 blood samples of patients treated with immunosuppressive drugs. The results were compared with those obtained by immunoassays.
RESULTS: The LC/MS/MS approach was found to provide linear, stable, precise, and accurate results, with lower limits of quantification of 12.5, 1.1, 1.2, and 1.2 μg/L for CSA, TACRO, SIRO, and EVE, respectively. With this method 80 samples were analysed and reported within a single work shift. A correlation was observed between the LC/MS/MS and immunoassay data, with Spearman correlation coefficients of 0.980 (n = 260) for CSA, 0.836 for TACRO (n = 562), 0.898 for SIRO (n = 113), and 0.904 for EVE (n = 257). Passing-Bablock regression showed the presence of constant and proportional biases for most of the drugs. A Blond-Altman graph showed differences between the assays, with immunoassays generally overestimating the drugs.
CONCLUSIONS: The LC/MS/MS certified kit was validated for the detection of immunosuppressant drugs in whole blood and it provided a high-throughput method that is consistent with the requirements of clinical laboratories. The comparison of patient data between LC/MS/MS and up-dated immunoassays shows that a significant discrepancy still exists, especially for CSA and SIRO, confirming the greater specificity associated with use of the LC/MS/MS assay Copyright © 2017 John Wiley & Sons, Ltd.
METHODS: A certified in vitro diagnostic kit coupled with a medical device LC/MS/MS was validated and applied to the analysis of 1192 blood samples of patients treated with immunosuppressive drugs. The results were compared with those obtained by immunoassays.
RESULTS: The LC/MS/MS approach was found to provide linear, stable, precise, and accurate results, with lower limits of quantification of 12.5, 1.1, 1.2, and 1.2 μg/L for CSA, TACRO, SIRO, and EVE, respectively. With this method 80 samples were analysed and reported within a single work shift. A correlation was observed between the LC/MS/MS and immunoassay data, with Spearman correlation coefficients of 0.980 (n = 260) for CSA, 0.836 for TACRO (n = 562), 0.898 for SIRO (n = 113), and 0.904 for EVE (n = 257). Passing-Bablock regression showed the presence of constant and proportional biases for most of the drugs. A Blond-Altman graph showed differences between the assays, with immunoassays generally overestimating the drugs.
CONCLUSIONS: The LC/MS/MS certified kit was validated for the detection of immunosuppressant drugs in whole blood and it provided a high-throughput method that is consistent with the requirements of clinical laboratories. The comparison of patient data between LC/MS/MS and up-dated immunoassays shows that a significant discrepancy still exists, especially for CSA and SIRO, confirming the greater specificity associated with use of the LC/MS/MS assay Copyright © 2017 John Wiley & Sons, Ltd.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app