Triple-Cut Computer-Aided Design-Computer-Aided Modeling: More Oncologic Safety Added to Precise Mandible Modeling.
PURPOSE: Computer-aided design-computer-aided modeling (CAD-CAM) has become standard in mandibular reconstruction because it offers better outcomes. Occasionally, the reconstructive plans need to be changed intraoperatively and the custom-made prefabricated devices may become inadequate. We present an efficient adjunct to the standard CAD-CAM technique that resolves this problem.
MATERIALS AND METHODS: Customized surgical devices with our "triple-cut" concept were used in 5 patients for mandibular reconstruction with free fibula flap (4 after mandibular resection for squamous cell carcinoma and 1 after mandibular osteoradionecrosis). In all patients the mandibular and fibular cutting guides were provided with 3 different cutting levels per side.
RESULTS: Three different cutting levels on the mandible permitted an accurate resection based on the intraoperative needs. The corresponding 3 "cutting levels" on the fibula created perfectly matching segments of vascularized bone. Good contact of bony segments was obtained in all patients.
CONCLUSIONS: The prefabricated triple-cut cutting guides make changing the dimensions of bony resection, while still using the prefabricated CAD-CAM reconstructive plate, possible.
MATERIALS AND METHODS: Customized surgical devices with our "triple-cut" concept were used in 5 patients for mandibular reconstruction with free fibula flap (4 after mandibular resection for squamous cell carcinoma and 1 after mandibular osteoradionecrosis). In all patients the mandibular and fibular cutting guides were provided with 3 different cutting levels per side.
RESULTS: Three different cutting levels on the mandible permitted an accurate resection based on the intraoperative needs. The corresponding 3 "cutting levels" on the fibula created perfectly matching segments of vascularized bone. Good contact of bony segments was obtained in all patients.
CONCLUSIONS: The prefabricated triple-cut cutting guides make changing the dimensions of bony resection, while still using the prefabricated CAD-CAM reconstructive plate, possible.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app