Method comparison and generation of plasma biochemistry RIs for the White rhinoceros on a point-of-care and wet chemistry analyzer.
Veterinary Clinical Pathology 2017 June
BACKGROUND: Plasma biochemistry analysis may aid the management of White rhinoceros with poaching or other injuries. Analyzer- and species-specific RIs are necessary to evaluate health status and identify abnormalities.
OBJECTIVES: The purpose of the study was to perform a comparison study between the IDEXX VetTest and Roche Cobas Integra 400 Plus, and to generate analyzer-specific RIs for White rhinoceros according to published guidelines.
METHODS: Comparison was carried out using White rhinoceros plasma samples from healthy and diseased animals. Reference intervals for albumin, ALT, AST, CK, creatinine, GGT, globulins, glucose, phosphorus, total proteins, and urea were determined from a sample group of chemically immobilized healthy adult White rhinoceros from the Kruger National Park, South Africa.
RESULTS: There was a significant analytic bias for all analytes between the 2 analyzers. Results for glucose and total protein were clinically equivalent based on total allowable error limits. Reference intervals were generated from 51 individuals (26 male, 25 female) for all analytes except ALT on the VetTest.
DISCUSSION: The type, direction, and magnitude of bias between the VetTest and Cobas appeared to be species- and analyzer-specific, when compared to other studies. These measures of bias may be used for comparability testing. Reference intervals for total proteins (VetTest 77-108 g/L, Cobas 77-110 g/L) and globulins (VetTest 47-79 g/L, Cobas 51-87 g/L) were high compared to other uneven-toed ungulates.
CONCLUSION: Plasma samples from White rhinoceros can be evaluated on both the VetTest and Cobas. Results from this study will aid conservation efforts directed toward this species.
OBJECTIVES: The purpose of the study was to perform a comparison study between the IDEXX VetTest and Roche Cobas Integra 400 Plus, and to generate analyzer-specific RIs for White rhinoceros according to published guidelines.
METHODS: Comparison was carried out using White rhinoceros plasma samples from healthy and diseased animals. Reference intervals for albumin, ALT, AST, CK, creatinine, GGT, globulins, glucose, phosphorus, total proteins, and urea were determined from a sample group of chemically immobilized healthy adult White rhinoceros from the Kruger National Park, South Africa.
RESULTS: There was a significant analytic bias for all analytes between the 2 analyzers. Results for glucose and total protein were clinically equivalent based on total allowable error limits. Reference intervals were generated from 51 individuals (26 male, 25 female) for all analytes except ALT on the VetTest.
DISCUSSION: The type, direction, and magnitude of bias between the VetTest and Cobas appeared to be species- and analyzer-specific, when compared to other studies. These measures of bias may be used for comparability testing. Reference intervals for total proteins (VetTest 77-108 g/L, Cobas 77-110 g/L) and globulins (VetTest 47-79 g/L, Cobas 51-87 g/L) were high compared to other uneven-toed ungulates.
CONCLUSION: Plasma samples from White rhinoceros can be evaluated on both the VetTest and Cobas. Results from this study will aid conservation efforts directed toward this species.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app