PURPOSE: To explore the characteristics that impact lung nodule detection by peripheral vision when searching for lung nodules on chest CT-scans.

METHODS: This study was approved by the local IRB and is HIPAA compliant. A simulated primary (1°) target mass (2 × 2 × 5 cm) was embedded into 5 cm thick subvolumes (SV) extracted from three unenhanced lung MDCT scans (64 row, 1.25 mm thickness, 0.7 mm increment). One of 30 solid, secondary nodules with either 3-4 mm and 5-8 mm diameters were embedded into 192 of 207 SVs. The secondary nodule was placed at a random depth within each SV, a transverse distance of 2.5, 5, 7.5, or 10 mm, and along one of eight rays cast every 45° from the center of the 1° mass. Video recordings of transverse paging in cranio-caudal direction were created for each SV (frame rate three sections/sec). Six radiologists observed each cine-loop once while gaze-tracking hardware assured that gaze was centered on the 1° mass. Each radiologist assigned a confidence rating (0-5) to the detection of a secondary nodule and indicated its location. Detection sensitivity was analyzed relative to secondary nodule size, transverse distance, radial orientation, and lung complexity. Lung complexity was characterized by the number of particles (connected pixels) and the sum of the area of all particles above a -500 HU threshold within regions of interest around the 1° mass and secondary nodule.

RESULTS: Using a proportional odds logistic regression model and eliminating redundant predictors, models fit individually to each reader resulted in the following decreasing order of association based on greatest reduction in Akaike Information Criterion: secondary nodule diameter (6/6 readers, P < 0.001), distance from central mass (6/6 readers, P < 0.001), lung complexity particle count (5/6 readers, P = 0.05), and lung complexity particle area (3/6 readers, P = 0.03). Substantial inter-reader differences in sensitivity to decreasing nodule diameter, distance, and complexity characteristics were observed.

CONCLUSIONS: Of the investigated parameters, secondary nodule size, distance from the gaze center and lung complexity (particle number and area) significantly impact nodule detection with peripheral vision.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app