Comparative Study
Journal Article
Add like
Add dislike
Add to saved papers

Stability of knee ligament complex of Thiel-embalmed cadaver compared to in vivo knee.

BACKGROUND: The first biomechanical evaluation of new implants is usually carried out with cadavers. Fixation of Thiel-embalmed cadavers is supposed to preserve the histological structure, colour and consistency of the tissue and has a low risk of infection and toxicity. However, the biomechanical properties of Thiel-fixated tissue are still unknown. The aim of this study was to quantify the effect of the Thiel-embalming method on the elastic properties of the ligament complex of the knee compared to in vivo knees during total knee arthroplasty.

METHODS: The results of biomechanical tensile tests with 10 Thiel-embalmed knees were compared with the findings of 10 patients who underwent total knee arthroplasty with a standardised knee balancer at our department. We reconstructed the force-elongation curves of the medial and lateral ligament complex and calculated the stiffness in direct correlation with overall soft tissue stability in full extension and in 90° of flexion.

RESULTS: All curves consisted of a non-linear part at the beginning and a linear part from about 80N onwards. In full extension, median stiffness in the cadavers was 26.6N/mm for the medial compartment and 31.6N/mm for the lateral compartment. The values for in vivo were 25.7N/mm for the medial compartment and 25.3N/mm for the lateral compartment (p=0.684 for the medial compartment and p=0.247 for the lateral compartment). In 90° of flexion, median stiffness in the cadaver group was 24.7N/mm for the medial compartment and 22.2N/mm for the lateral compartment. In vivo, median stiffness was 30.3N/mm for the medial compartment and 29.2N/mm for the lateral compartment (p=0.009 for the medial compartment and p=0.143 for the lateral compartment).

CONCLUSION: Stiffness of the medial and lateral ligament complex in the knee was comparable between Thiel-embalmed cadavers and in vivo patients during total knee arthroplasty. Thiel fixation seems to preserve the soft tissue properties similar to those in vivo.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app