Radiological Results and Clinical Patient Outcome After Implantation of a Hydraulic Expandable Vertebral Body Replacement following Traumatic Vertebral Fractures in the Thoracic and Lumbar Spine: A 3-Year Follow-Up.

Spine 2017 April 16
STUDY DESIGN: A prospective monocentric study.

OBJECTIVE: The aim of the current study was the analysis of patient outcome and radiological results 3 years after implantation of a hydraulic expandable vertebral body replacement (VBR) system.

SUMMARY OF BACKGROUND DATA: Around 70% to 90% of all traumatic spinal fractures are located in the thoracic and lumbar spine. Dorso-ventral stabilization is a frequently used procedure in traumatic vertebral body fracture treatment. VBR systems can be used to bridge bony defects. In the current study, a new VBR expanded by water pressure with adjustable endplates is used.

METHODS: All patients who suffered a singular traumatic fracture to a thoracic or lumbar vertebral body (Th 5-L 5) in the period from November 2009 to December 2010 and (i) underwent dorsal instrumentation and (ii) afterwards received the implantation of a hydraulic VBR were included in this study. The clinical outcome (visual analogue scale [VAS] spine score, questionnaire) and radiological findings (sagittal angle, implant subsidence, and implant position) 3 years after implantation were analyzed.

RESULTS: The follow-up was successful for n = 47 patients (follow-up rate: 89%). Most of the patients (n = 40) were "generally/very satisfied" with their outcome. The mean rating of the VAS spine score was 65.2 ± 23.1 (range: 20.5-100.0). The analysis of the radiological data showed an average subsidence of the implants of 1.1 ± 1.2 mm (range 0.0-5.0 mm). After the initial operation, the local sagittal angle remained stable in the follow-up 3 years later both for the thoracic spine and lumbar spine. Furthermore, no change in the implant's position was observed.

CONCLUSION: The implantation of a hydraulically expandable VBR allows a permanent stable fixation after traumatic fractures of the thoracic and lumbar spine.

LEVEL OF EVIDENCE: 2.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app