JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Prostate Cancer: Diffusion-weighted MR Imaging for Detection and Assessment of Aggressiveness-Comparison between Conventional and Kurtosis Models.

Radiology 2017 July
Purpose To compare standard diffusion-weighted (DW) imaging and diffusion kurtosis (DK) imaging for prostate cancer (PC) detection and characterization in a large patient cohort, with attention to the potential added value of DK imaging. Materials and Methods This retrospective institutional review board-approved study received a waiver of informed consent. Two hundred eighty-five patients with PC underwent 3.0-T phased-array coil prostate magnetic resonance (MR) imaging, including a DK imaging sequence (b values 0, 500, 1000, 1500, and 2000 sec/mm2 ) before prostatectomy. Maps of apparent diffusion coefficient (ADC) and diffusional kurtosis (K) were derived by using maximal b values of 1000 and 2000 sec/mm2 , respectively. Mean ADC and K were obtained from volumes of interest (VOIs) placed on each patient's dominant tumor and benign prostate tissue. Metrics were compared between benign and malignant tissue, between Gleason score (GS) ≤ 3 + 3 and GS ≥ 3 + 4 tumors, and between GS ≤ 3 + 4 and GS ≥ 4 + 3 tumors by using paired t tests, analysis of variance, receiver operating characteristic (ROC) analysis, and exact tests. Results ADC and K showed significant differences for benign versus tumor tissues, GS ≤ 3 + 3 versus GS ≥ 3 + 4 tumors, and GS ≤ 3 + 4 versus GS ≥ 4 + 3 tumors (P < .001 for all). ADC and K were highly correlated (r = -0.82; P < .001). Area under the ROC curve was significantly higher (P = .002) for ADC (0.921) than for K (0.902) for benign versus malignant tissue but was similar for GS ≤ 3 + 3 versus GS ≥ 3 + 4 tumors (0.715-0.744) and GS ≤ 3 + 4 versus GS ≥ 4 + 3 tumors (0.694-0.720) (P > .15). ADC and K were concordant for these various outcomes in 80.0%-88.6% of patients; among patients with discordant results, ADC showed better performance than K for GS ≤ 3 + 4 versus GS ≥ 4 + 3 tumors (P = .016) and was similar to K for other outcomes (P > .136). Conclusion ADC and K were highly correlated, had similar diagnostic performance, and were concordant for the various outcomes in the large majority of cases. These observations did not show a clear added value of DK imaging compared with standard DW imaging for clinical PC evaluation. © RSNA, 2017 Online supplemental material is available for this article.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app