Reproducibility of inspiratory muscle endurance testing using PowerBreathe for COPD patients.
Physiotherapy Research International : the Journal for Researchers and Clinicians in Physical Therapy 2018 January
BACKGROUND: Assessing the strength and endurance of respiratory muscles is fundamental for characterizing respiratory muscle dysfunction. Although a variety of tests are used to evaluate respiratory muscle endurance, not all of them are applicable in clinical practice. Assessments can be made using a practical device called PowerBreathe®, but its reproducibility has not been tested in chronic obstructive pulmonary disease (COPD) patients.
AIM: To verify the reproducibility of the inspiratory muscle endurance test using a manometer and PowerBreathe® in COPD patients.
METHODS: A cross-sectional study was used. In total, 19 moderate-severe COPD patients, male and female, aged 50 to 80 years took part in the research. This evaluation consisted of 2 tests: an incremental test and a constant one held on the same day and repeated after 48 hr. The incremental test started with 10-cm H2 O, adding 10-cm H2 O every 2 min and taking 1 min of rest before increasing the load. The highest load that could be sustained for at least 1 min was considered the sustained maximum inspiratory pressure (SMIP) value. The constant test was performed at an intensity of 80% of the SMIP and the maximum time limit was 30 min.
RESULTS: In the incremental test, there was a significant increase in the SMIP compared to the test-retest (61 ± 24/64.7 ± 23.8; p = .015); the value of the relative reproducibility was 0.96, the standard error of the absolute measurement was 4.7 (95% confidence interval 9.2), and the minimum detectable difference was 10.9. In the Bland-Altman analysis, the mean error was 4.2 (confidence interval -7.6 to 16.1). The constant test was not reproducible.
CONCLUSION: It was observed that the incremental test was reproducible to evaluate inspiratory muscle endurance in COPD patients. Furthermore, 2 tests needed to be carried out due to the learning effect.
AIM: To verify the reproducibility of the inspiratory muscle endurance test using a manometer and PowerBreathe® in COPD patients.
METHODS: A cross-sectional study was used. In total, 19 moderate-severe COPD patients, male and female, aged 50 to 80 years took part in the research. This evaluation consisted of 2 tests: an incremental test and a constant one held on the same day and repeated after 48 hr. The incremental test started with 10-cm H2 O, adding 10-cm H2 O every 2 min and taking 1 min of rest before increasing the load. The highest load that could be sustained for at least 1 min was considered the sustained maximum inspiratory pressure (SMIP) value. The constant test was performed at an intensity of 80% of the SMIP and the maximum time limit was 30 min.
RESULTS: In the incremental test, there was a significant increase in the SMIP compared to the test-retest (61 ± 24/64.7 ± 23.8; p = .015); the value of the relative reproducibility was 0.96, the standard error of the absolute measurement was 4.7 (95% confidence interval 9.2), and the minimum detectable difference was 10.9. In the Bland-Altman analysis, the mean error was 4.2 (confidence interval -7.6 to 16.1). The constant test was not reproducible.
CONCLUSION: It was observed that the incremental test was reproducible to evaluate inspiratory muscle endurance in COPD patients. Furthermore, 2 tests needed to be carried out due to the learning effect.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app