Diagnostic accuracy of dual-energy computed tomography in patients with gout: A meta-analysis.
Seminars in Arthritis and Rheumatism 2017 August
OBJECTIVE: This study aimed to evaluate the diagnostic performance of dual-energy computed tomography (DECT) for patients with gout.
METHODS: We searched the Medline, Embase, and Cochrane Library databases, and performed a meta-analysis on the diagnostic accuracy of DECT in patients with gout.
RESULTS: A total of eight studies including 510 patients with gout and 268 controls (patients with non-gout inflammatory arthritis) were available for the meta-analysis. The pooled sensitivity and specificity of DECT were 84.7% (95% confidence interval [CI]: 81.3-87.7) and 93.7% (93.0-96.3), respectively. The positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 9.882 (6.122-15.95), 0.163 (0.097-0.272), and 78.10 (31.14-195.84), respectively. The area under the curve of DECT was 0.956 and the Q* index was 0.889, indicating a high diagnostic accuracy. Some between-study heterogeneity was found in the meta-analyses. However, there was no evidence of a threshold effect (Spearman correlation coefficient = 0.419; p = 0.035). In addition, meta-regression showed that the sample size, study design, and diagnostic criteria were not sources of heterogeneity, and subgroup meta-analyses did not change the overall diagnostic accuracy.
CONCLUSIONS: Our meta-analysis of published studies demonstrates that DECT has a high diagnostic accuracy and plays an important role in the diagnosis of gout.
METHODS: We searched the Medline, Embase, and Cochrane Library databases, and performed a meta-analysis on the diagnostic accuracy of DECT in patients with gout.
RESULTS: A total of eight studies including 510 patients with gout and 268 controls (patients with non-gout inflammatory arthritis) were available for the meta-analysis. The pooled sensitivity and specificity of DECT were 84.7% (95% confidence interval [CI]: 81.3-87.7) and 93.7% (93.0-96.3), respectively. The positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 9.882 (6.122-15.95), 0.163 (0.097-0.272), and 78.10 (31.14-195.84), respectively. The area under the curve of DECT was 0.956 and the Q* index was 0.889, indicating a high diagnostic accuracy. Some between-study heterogeneity was found in the meta-analyses. However, there was no evidence of a threshold effect (Spearman correlation coefficient = 0.419; p = 0.035). In addition, meta-regression showed that the sample size, study design, and diagnostic criteria were not sources of heterogeneity, and subgroup meta-analyses did not change the overall diagnostic accuracy.
CONCLUSIONS: Our meta-analysis of published studies demonstrates that DECT has a high diagnostic accuracy and plays an important role in the diagnosis of gout.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app