Cavity theory applications for kilovoltage cellular dosimetry.

Relationships between macroscopic (bulk tissue) and microscopic (cellular) dose descriptors are investigated using cavity theory and Monte Carlo (MC) simulations. Small, large, and multiple intermediate cavity theory (SCT, LCT, and ICT, respectively) approaches are considered for 20 to 370 keV incident photons; ICT is a sum of SCT and LCT contributions weighted by parameter d. Considering μm-sized cavities of water in bulk tissue phantoms, different cavity theory approaches are evaluated via comparison of [Formula: see text] (where D w,m is dose-to-water-in-medium and D m,m is dose-to-medium-in-medium) with MC results. The best overall agreement is achieved with an ICT approach in which [Formula: see text], where L is the mean chord length of the cavity and β is given by [Formula: see text] (R CSDA is the continuous slowing down approximation range of an electron of energy equal to that of incident photons). Cell nucleus doses, D nuc , computed with this ICT approach are compared with those from MC simulations involving multicellular soft tissue models considering a representative range of cell/nucleus sizes and elemental compositions. In [Formula: see text] of cases, ICT and MC predictions agree within [Formula: see text]; disagreement is at most 8.8%. These results suggest that cavity theory may be useful for linking doses from model-based dose calculation algorithms (MBDCAs) with energy deposition in cellular targets. Finally, based on the suggestion that clusters of water molecules associated with DNA are important radiobiological targets, two approaches for estimating dose-to-water by application of SCT to MC results for D m,m or D nuc are compared. Results for these two estimates differ by up to [Formula: see text], demonstrating the sensitivity of energy deposition within a small volume of water in nucleus to the geometry and composition of its surroundings. In terms of the debate over the dose specification medium for MBDCAs, these results do not support conversion of D m,m to D w,m using SCT.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app