Add like
Add dislike
Add to saved papers

Characterization of Small Focal Renal Lesions: Diagnostic Accuracy with Single-Phase Contrast-enhanced Dual-Energy CT with Material Attenuation Analysis Compared with Conventional Attenuation Measurements.

Radiology 2017 September
Purpose To determine whether single-phase contrast material-enhanced dual-energy material attenuation analysis improves the characterization of small (1-4 cm) renal lesions compared with conventional attenuation measurements by using histopathologic analysis and follow-up imaging as the clinical reference standards. Materials and Methods In this retrospective, HIPAA-compliant, institutional review board-approved study, 136 consecutive patients (95 men and 41 women; mean age, 54 years) with 144 renal lesions (111 benign, 33 malignant) measuring 1-4 cm underwent single-energy unenhanced and contrast-enhanced dual-energy computed tomography (CT) of the abdomen. For each renal lesion, attenuation measurements were obtained; attenuation change of greater than or equal to 15 HU was considered evidence of enhancement. Dual-energy attenuation measurements were also obtained by using iodine-water, water-iodine, calcium-water, and water-calcium material basis pairs. Mean lesion attenuation values and material densities were compared between benign and malignant renal lesions by using the two-sample t test. Diagnostic accuracy of attenuation measurements and dual-energy material densities was assessed and validated by using 10-fold cross-validation to limit the effect of optimistic bias. Results By using cross-validated optimal thresholds at 100% sensitivity, iodine-water material attenuation images significantly improved specificity for differentiating between benign and malignant renal lesions compared with conventional enhancement measurements (93% [103 of 111]; 95% confidence interval: 86%, 97%; vs 81% [90 of 111]; 95% confidence interval: 73%, 88%) (P = .02). Sensitivity with iodine-water and calcium-water material attenuation images was also higher than that with conventional enhancement measurements, although the difference was not statistically significant. Conclusion Contrast-enhanced dual-energy CT with material attenuation analysis improves specificity for characterization of small (1-4 cm) renal lesions compared with conventional attenuation measurements. © RSNA, 2017 Online supplemental material is available for this article.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app