Transfer learning from RF to B-mode temporal enhanced ultrasound features for prostate cancer detection.
PURPOSE: We present a method for prostate cancer (PCa) detection using temporal enhanced ultrasound (TeUS) data obtained either from radiofrequency (RF) ultrasound signals or B-mode images.
METHODS: For the first time, we demonstrate that by applying domain adaptation and transfer learning methods, a tissue classification model trained on TeUS RF data (source domain) can be deployed for classification using TeUS B-mode data alone (target domain), where both data are obtained on the same ultrasound scanner. This is a critical step for clinical translation of tissue classification techniques that primarily rely on accessing RF data, since this imaging modality is not readily available on all commercial scanners in clinics. Proof of concept is provided for in vivo characterization of PCa using TeUS B-mode data, where different nonlinear processing filters in the pipeline of the RF to B-mode conversion result in a distribution shift between the two domains.
RESULTS: Our in vivo study includes data obtained in MRI-guided targeted procedure for prostate biopsy. We achieve comparable area under the curve using TeUS RF and B-mode data for medium to large cancer tumor sizes in biopsy cores (>4 mm).
CONCLUSION: Our result suggests that the proposed adaptation technique is successful in reducing the divergence between TeUS RF and B-mode data.
METHODS: For the first time, we demonstrate that by applying domain adaptation and transfer learning methods, a tissue classification model trained on TeUS RF data (source domain) can be deployed for classification using TeUS B-mode data alone (target domain), where both data are obtained on the same ultrasound scanner. This is a critical step for clinical translation of tissue classification techniques that primarily rely on accessing RF data, since this imaging modality is not readily available on all commercial scanners in clinics. Proof of concept is provided for in vivo characterization of PCa using TeUS B-mode data, where different nonlinear processing filters in the pipeline of the RF to B-mode conversion result in a distribution shift between the two domains.
RESULTS: Our in vivo study includes data obtained in MRI-guided targeted procedure for prostate biopsy. We achieve comparable area under the curve using TeUS RF and B-mode data for medium to large cancer tumor sizes in biopsy cores (>4 mm).
CONCLUSION: Our result suggests that the proposed adaptation technique is successful in reducing the divergence between TeUS RF and B-mode data.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app