EVALUATION STUDIES
JOURNAL ARTICLE
Add like
Add dislike
Add to saved papers

Use of a Novel, Portable, LED-Based Capillary Refill Time Simulator within a Disaster Triage Context.

Introduction A simple, portable capillary refill time (CRT) simulator is not commercially available. This device would be useful in mass-casualty simulations with multiple volunteers or mannequins depicting a variety of clinical findings and CRTs. The objective of this study was to develop and evaluate a prototype CRT simulator in a disaster simulation context.

METHODS: A CRT prototype simulator was developed by embedding a pressure-sensitive piezo crystal, and a single red light-emitting diode (LED) light was embedded, within a flesh-toned resin. The LED light was programmed to turn white proportionate to the pressure applied, and gradually to return to red on release. The time to color return was adjustable with an external dial. The prototype was tested for feasibility among two cohorts: emergency medicine physicians in a tabletop exercise and second year medical students within an actual disaster triage drill. The realism of the simulator was compared to video-based CRT, and participants used a Visual Analog Scale (VAS) ranging from "completely artificial" to "as if on a real patient." The VAS evaluated both the visual realism and the functional (eg, tactile) realism. Accuracy of CRT was evaluated only by the physician cohort. Data were analyzed using parametric and non-parametric statistics, and mean Cohen's Kappas were used to describe inter-rater reliability.

RESULTS: The CRT simulator was generally well received by the participants. The simulator was perceived to have slightly higher functional realism (P=.06, P=.01) but lower visual realism (P=.002, P=.11) than the video-based CRT. Emergency medicine physicians had higher accuracy on portrayed CRT on the simulator than the videos (92.6% versus 71.1%; P<.001). Inter-rater reliability was higher for the simulator (0.78 versus 0.27; P<.001).

CONCLUSIONS: A simple, LED-based CRT simulator was well received in both settings. Prior to widespread use for disaster triage training, validation on participants' ability to accurately triage disaster victims using CRT simulators and video-based CRT simulations should be performed. Chang TP , Santillanes G , Claudius I , Pham PK , Koved J , Cheyne J , Gausche-Hill M , Kaji AH , Srinivasan S , Donofrio JJ , Bir C . Use of a novel, portable, LED-based capillary refill time simulator within a disaster triage context. Prehosp Disaster Med. 2017;32(4):451-456.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app