Comparison of commercial methods of immunoblot, ELISA, and chemiluminescent immunoassay for detecting type-specific herpes simplex viruses-1 and -2 IgG.
Journal of Clinical Laboratory Analysis 2018 January
BACKGROUND: Serology for type-specific herpes simplex virus (HSV) is based on the use of the respective glycoprotein G (gG).
METHODS: Chemiluminescent immunoassay (CLIA; BIO-FLASH® , Biokit, Spain), ELISA (HerpeSelect® , Focus, USA), and immunoblot (IB; Virotech, Germany) for detecting HSV-1- and HSV-2-specific IgG were compared using 384 serum samples received for HSV serology. The samples were classified as positive or negative according to a consensus criterion.
RESULTS: For HSV-1, 262 samples were positive and 118 were negative (four samples were unclassifiable). IB showed agreement, sensitivity, and specificity values of 98.68%, 98.47% and 99.15%, respectively. The corresponding figures for CLIA and ELISA were 98.95%, 99.24% and 98.31%, and 98.16%, 99.62% and 94.92%, respectively. For HSV-2, 106 samples were positive and 278 were negative. Agreement, sensitivity, and specificity of IB were 99.48%, 98.11%, and 100%, respectively. The corresponding figures for CLIA and ELISA were 99.48%, 99.06% and 99.64%, and 98.18%, 99.06% and 97.84%, respectively.
CONCLUSION: The three methods showed excellent and equivalent performance characteristics for the detection of type-specific IgG to HSV-1 and HSV-2.
METHODS: Chemiluminescent immunoassay (CLIA; BIO-FLASH® , Biokit, Spain), ELISA (HerpeSelect® , Focus, USA), and immunoblot (IB; Virotech, Germany) for detecting HSV-1- and HSV-2-specific IgG were compared using 384 serum samples received for HSV serology. The samples were classified as positive or negative according to a consensus criterion.
RESULTS: For HSV-1, 262 samples were positive and 118 were negative (four samples were unclassifiable). IB showed agreement, sensitivity, and specificity values of 98.68%, 98.47% and 99.15%, respectively. The corresponding figures for CLIA and ELISA were 98.95%, 99.24% and 98.31%, and 98.16%, 99.62% and 94.92%, respectively. For HSV-2, 106 samples were positive and 278 were negative. Agreement, sensitivity, and specificity of IB were 99.48%, 98.11%, and 100%, respectively. The corresponding figures for CLIA and ELISA were 99.48%, 99.06% and 99.64%, and 98.18%, 99.06% and 97.84%, respectively.
CONCLUSION: The three methods showed excellent and equivalent performance characteristics for the detection of type-specific IgG to HSV-1 and HSV-2.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app