We have located links that may give you full text access.
Comparison between endobronchial ultrasound-guided transbronchial biopsy and CT-guided transthoracic lung biopsy for the diagnosis of peripheral lung cancer: a systematic review and meta-analysis.
Translational Lung Cancer Research 2017 Februrary
BACKGROUND: With the release of the National Lung Screening Trial results, the detection of peripheral pulmonary lesions (PPLs) is likely to increase. Computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB) and radial probe endobronchial ultrasound (r-EBUS)-guided transbronchial lung biopsy (TBLB) are recommended for tissue diagnosis of PPLs.
METHODS: A systematic review of published literature evaluating the accuracy of r-EBUS-TBLB and CT-PTNB for the diagnosis of PPLs was performed to determine point sensitivity and specificity, and to construct a summary receiver-operating characteristic curve.
RESULTS: This review included 31 publications dealing with EBUS-TBLB and 14 publications dealing with CT-PTNB for the diagnosis of PPLs. EBUS-TBLB had point sensitivity of 0.69 (95% CI: 0.67-0.71) for the diagnosis of peripheral lung cancer (PLC), which was lower than the sensitivity of CT-PTNB (0.94, 95% CI: 0.94-0.95). However, the complication rates observed with EBUS-TBLB were lower than those reported for CT-PTNB.
CONCLUSIONS: This meta-analysis showed that EBUS-TBLB is a safe and relatively accurate tool in the investigation of PLC. Although the yield remains lower than that of CT-PTNB, the procedural risks are lower.
METHODS: A systematic review of published literature evaluating the accuracy of r-EBUS-TBLB and CT-PTNB for the diagnosis of PPLs was performed to determine point sensitivity and specificity, and to construct a summary receiver-operating characteristic curve.
RESULTS: This review included 31 publications dealing with EBUS-TBLB and 14 publications dealing with CT-PTNB for the diagnosis of PPLs. EBUS-TBLB had point sensitivity of 0.69 (95% CI: 0.67-0.71) for the diagnosis of peripheral lung cancer (PLC), which was lower than the sensitivity of CT-PTNB (0.94, 95% CI: 0.94-0.95). However, the complication rates observed with EBUS-TBLB were lower than those reported for CT-PTNB.
CONCLUSIONS: This meta-analysis showed that EBUS-TBLB is a safe and relatively accurate tool in the investigation of PLC. Although the yield remains lower than that of CT-PTNB, the procedural risks are lower.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app