We have located links that may give you full text access.
Journal Article
Multicenter Study
Validation Studies
Follow-Up Study on Fetal CT Radiation Dose in Japan: Validating the Decrease in Radiation Dose.
AJR. American Journal of Roentgenology 2017 April
OBJECTIVE: In 2011, we collected data on fetal CT radiation dose to determine the diagnostic reference level (DRL); however, continuous evaluation of the DRL is necessary. The hypothesis of this study is that the fetal CT radiation dose has decreased, and we predict a widespread use of iterative reconstruction (IR). We also predict that the national decrease in exposure is because of the DRL reported as a result of the previous national study.
MATERIALS AND METHODS: Various testing protocols from each site were summarized as part of the study results. The minimum, one-fourth (25th percentile), median, three-fourths (75th percentile), and maximum values were obtained for volume CT dose index (CTDIvol), dose-length product (DLP), and scan length of 120 fetal CT examinations. The trends for IR usage and tube voltage were also investigated.
RESULTS: Compared to the results of the 2011 study (n = 119), the minimum, 25th percentile, median, and 75th percentile values for CTDIvol and DLP have decreased for the tabulated results in 2015 (n = 120). The 75th percentile value for CTDIvol was 4.9 mGy, which is 43% of the previous value. IR was used in 70% of the sites. The radiation dose was significantly lower among groups that used IR.
CONCLUSION: Four years passed between our initial survey on DRL and the present follow-up survey, and it appears that the previous report sufficiently fulfilled its objective and role in contributing to the decrease in DRL observed in this follow-up study.
MATERIALS AND METHODS: Various testing protocols from each site were summarized as part of the study results. The minimum, one-fourth (25th percentile), median, three-fourths (75th percentile), and maximum values were obtained for volume CT dose index (CTDIvol), dose-length product (DLP), and scan length of 120 fetal CT examinations. The trends for IR usage and tube voltage were also investigated.
RESULTS: Compared to the results of the 2011 study (n = 119), the minimum, 25th percentile, median, and 75th percentile values for CTDIvol and DLP have decreased for the tabulated results in 2015 (n = 120). The 75th percentile value for CTDIvol was 4.9 mGy, which is 43% of the previous value. IR was used in 70% of the sites. The radiation dose was significantly lower among groups that used IR.
CONCLUSION: Four years passed between our initial survey on DRL and the present follow-up survey, and it appears that the previous report sufficiently fulfilled its objective and role in contributing to the decrease in DRL observed in this follow-up study.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app