Add like
Add dislike
Add to saved papers

Reliability of the grip strength coefficient of variation for detecting sincerity in normal and blocked median nerve in healthy adults.

In the assessment of hand and upper limb function, detecting sincerity of effort (SOE) for grip strength is of major importance to identifying feigned loss of strength. Measuring maximal grip strength with a dynamometer is very common, often combined with calculating the coefficient of variation (CV), a measure of the variation over the three grip strength trials. Little data is available about the relevance of these measurements in patients with median nerve impairment due to the heterogeneity of patient groups. This study examined the reliability of grip strength tests as well as the CV to detect SOE in healthy subjects. The power distribution of the individual fingers and the thenar was taken into account. To assess reliability, the measurements were performed in subjects with a median nerve block to simulate a nerve injury. The ability of 21 healthy volunteers to exert maximal grip force and to deliberately exert half-maximal force to simulate reduced SOE in a power grip was examined using the Jamar® dynamometer. The experiment was performed in a combined setting with and without median nerve block of the same subject. The force at the fingertips of digits 2-5 and at the thenar eminence was measured with a sensor glove with integrated pressure receptors. For each measurement, three trials were recorded subsequently and the mean and CV were calculated. When exerting submaximal force, the subjects reached 50-62% of maximal force, regardless of the median nerve block. The sensor glove revealed a significant reduction of force when exerting submaximal force (P1 sensor) with (P<0.032) and without median nerve block (P<0.017). An increase in CV at submaximal force was found, although it was not significant. SOE can be detected with the CV at the little finger at using a 10% cut-off (sensitivity 0.84 and 0.92 without and with median nerve block, respectively). These findings suggest low reliability of the power grip measurement with the Jamar® dynamometer, as well as that of the CV for detecting SOE. However, the combination of finger forces including the thenar area and the CV at the little finger could lead to better reliability for detecting feigned reduction of grip strength. The methods were as reliable in subjects with a median nerve block as in healthy subjects.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app