PURPOSE: The Colorado Retinopathy of Prematurity Screening Algorithm (CO-ROP) recommends screening for infants meeting the following criteria for retinopathy of prematurity (ROP): gestational age ≤30 weeks, birth weight of ≤1500 g, and net weight gain of ≤650 g between birth and 4 weeks of age. This study was performed to evaluate the validity of CO-ROP in a tertiary referral county hospital.
METHODS: CO-ROP was used to retrospectively analyze the data from consecutive newborns screened for ROP using national screening guidelines at Parkland Hospital, Dallas, Texas, between April 1, 2009, to August 30, 2013. Sensitivities and specificities for identifying ROP were calculated.
RESULTS: A total of 374 infants were included, of whom 29 (7.8%) developed type 1 ROP and 12 (3.2%) developed type 2 ROP. The CO-ROP model would have decreased number of infants screened by 34% compared to current national screening criteria. CO-ROP had sensitivity of 93.1% (95% CI, 77.2-99.1) and 92.7% (95% CI, 61.5-99.8) for identifying type 1 and type 2 ROP, respectively. Of 29 patients who developed type 1 ROP, 2 were not identified using CO-ROP.
CONCLUSIONS: The CO-ROP model significantly reduced total number screened but failed to detect 2 infants with type 1 ROP, suggesting the need for further modification of the algorithm.
METHODS: CO-ROP was used to retrospectively analyze the data from consecutive newborns screened for ROP using national screening guidelines at Parkland Hospital, Dallas, Texas, between April 1, 2009, to August 30, 2013. Sensitivities and specificities for identifying ROP were calculated.
RESULTS: A total of 374 infants were included, of whom 29 (7.8%) developed type 1 ROP and 12 (3.2%) developed type 2 ROP. The CO-ROP model would have decreased number of infants screened by 34% compared to current national screening criteria. CO-ROP had sensitivity of 93.1% (95% CI, 77.2-99.1) and 92.7% (95% CI, 61.5-99.8) for identifying type 1 and type 2 ROP, respectively. Of 29 patients who developed type 1 ROP, 2 were not identified using CO-ROP.
CONCLUSIONS: The CO-ROP model significantly reduced total number screened but failed to detect 2 infants with type 1 ROP, suggesting the need for further modification of the algorithm.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app