We have located links that may give you full text access.
Metallic Stent Expansion Rate at Day One Predicts Stent Patency in Patients with Gastric Outlet Obstruction.
Digestive Diseases and Sciences 2017 May
BACKGROUND AND AIMS: Self-expandable metallic stent insertion has been a mainstream treatment for relieving the obstructive symptoms of malignant gastric outlet obstruction (MGOO), a late-stage complication of gastrointestinal malignancies. This study aims to investigate the predictive value of stent expansion rates in clinical outcomes in patients with MGOO.
METHODS: Eighty-seven patients with inoperable MGOO receiving metallic stents were reviewed retrospectively from April 2010 to December 2014. Clinical outcomes, predictors of stent patency, and survival were analyzed.
RESULTS: The technical and clinical success rates were 100 and 94.3%, respectively. The median stent patency time was 114 days (range 13-570 days). The median survival time was 133 days (range 13-1145 days). Stent dysfunctions occurred in 28 patients (32.2%), with restenosis accounting for the majority (82%). The stent expansion rate ≥75% at Day 1 predicted the stent patency [hazard ratio (HR) 0.12, P = 0.04]. However, it did not correlate with survival. Non-gastric cancer origins (HR 2.41, P = 0.002) and peritoneal carcinomatosis (HR 2.54, P = 0.001) correlated with poor survival. However, post-stent chemotherapy (HR 0.55, P = 0.03) was related to better outcome. The comparison of clinical outcomes of first and second stent insertions showed no significant difference in the stent expansion rate either at Day 0 and Day 1 (P = 0.97 and P = 0.57).
CONCLUSIONS: Self-expandable metallic stent insertion is a safe and effective treatment for relieving the obstructive symptoms. The stent expansion rate ≥75% at Day 1 is a novel stent-related predictor of stent patency.
METHODS: Eighty-seven patients with inoperable MGOO receiving metallic stents were reviewed retrospectively from April 2010 to December 2014. Clinical outcomes, predictors of stent patency, and survival were analyzed.
RESULTS: The technical and clinical success rates were 100 and 94.3%, respectively. The median stent patency time was 114 days (range 13-570 days). The median survival time was 133 days (range 13-1145 days). Stent dysfunctions occurred in 28 patients (32.2%), with restenosis accounting for the majority (82%). The stent expansion rate ≥75% at Day 1 predicted the stent patency [hazard ratio (HR) 0.12, P = 0.04]. However, it did not correlate with survival. Non-gastric cancer origins (HR 2.41, P = 0.002) and peritoneal carcinomatosis (HR 2.54, P = 0.001) correlated with poor survival. However, post-stent chemotherapy (HR 0.55, P = 0.03) was related to better outcome. The comparison of clinical outcomes of first and second stent insertions showed no significant difference in the stent expansion rate either at Day 0 and Day 1 (P = 0.97 and P = 0.57).
CONCLUSIONS: Self-expandable metallic stent insertion is a safe and effective treatment for relieving the obstructive symptoms. The stent expansion rate ≥75% at Day 1 is a novel stent-related predictor of stent patency.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app