We have located links that may give you full text access.
High-pitch low-dose abdominopelvic CT with tin-filtration technique for detecting urinary stones.
Abdominal Radiology 2017 August
OBJECTIVES: To evaluate urinary stone detection, radiation exposure, image quality, breathing-motion artifacts, and scanning time with high-pitch tin filter-based abdominopelvic CT.
METHODS: Sixty-three consecutive patients with urolithiasis underwent non-enhanced abdominopelvic CT with both regular (120 kV, pitch 0.6) and low-dose (Sn150kV, pitch 3.0) protocols on a third-generation dual-source CT. Stone characteristics, image noise (SD), signal-to-noise ratio (SNR), subjective image quality on a 5-point likert scale breathing-motion artifacts, and scanning time were evaluated. Volume CT dose index (CTDIvol), dose-length product (DLP), effective dose (ED) were compared.
RESULTS: A total of 157 urinary stones were detected by regular protocol; 154 were correctly identified by low-dose protocol with an overall detection rate of 98.1%. No significant differences were observed in SD, SNR, or subjective image quality between two protocols (P > 0.05). Compared to regular protocol, CTDIvol and ED were 56.6% (7.19 vs. 3.12 mGy, P < 0.001) and 55.6% (5.25 vs. 2.33 mSv, P < 0.001) lower; scanning time was 89.5% (7.9 vs. 0.83, P < 0.001) shorter; and breathing-motion artifacts were fewer (8 vs. 0 patients) with low-dose protocol.
CONCLUSIONS: High-pitch abdominopelvic CT with Sn150kV substantially reduced radiation exposure and scanning time, while maintained stone detection and image quality and prevented breathing-motion artifacts.
METHODS: Sixty-three consecutive patients with urolithiasis underwent non-enhanced abdominopelvic CT with both regular (120 kV, pitch 0.6) and low-dose (Sn150kV, pitch 3.0) protocols on a third-generation dual-source CT. Stone characteristics, image noise (SD), signal-to-noise ratio (SNR), subjective image quality on a 5-point likert scale breathing-motion artifacts, and scanning time were evaluated. Volume CT dose index (CTDIvol), dose-length product (DLP), effective dose (ED) were compared.
RESULTS: A total of 157 urinary stones were detected by regular protocol; 154 were correctly identified by low-dose protocol with an overall detection rate of 98.1%. No significant differences were observed in SD, SNR, or subjective image quality between two protocols (P > 0.05). Compared to regular protocol, CTDIvol and ED were 56.6% (7.19 vs. 3.12 mGy, P < 0.001) and 55.6% (5.25 vs. 2.33 mSv, P < 0.001) lower; scanning time was 89.5% (7.9 vs. 0.83, P < 0.001) shorter; and breathing-motion artifacts were fewer (8 vs. 0 patients) with low-dose protocol.
CONCLUSIONS: High-pitch abdominopelvic CT with Sn150kV substantially reduced radiation exposure and scanning time, while maintained stone detection and image quality and prevented breathing-motion artifacts.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app