Deriving detector-specific correction factors for rectangular small fields using a scintillator detector.

The goal of this study was to investigate small field output factors (OFs) for flattening filter-free (FFF) beams on a dedicated stereotactic linear accelerator-based system. From this data, the collimator exchange effect was quantified, and detector-specific correction factors were generated. Output factors for 16 jaw-collimated small fields (from 0.5 to 2 cm) were measured using five different detectors including an ion chamber (CC01), a stereotactic field diode (SFD), a diode detector (Edge), Gafchromic film (EBT3), and a plastic scintillator detector (PSD, W1). Chamber, diodes, and PSD measurements were performed in a Wellhofer water tank, while films were irradiated in solid water at 100 cm source-to-surface distance and 10 cm depth. The collimator exchange effect was quantified for rectangular fields. Monte Carlo (MC) simulations of the measured configurations were also performed using the EGSnrc/DOSXYZnrc code. Output factors measured by the PSD and verified against film and MC calculations were chosen as the benchmark measurements. Compared with plastic scintillator detector (PSD), the small volume ion chamber (CC01) underestimated output factors by an average of -1.0%±4.9%(max.=-11.7% for 0.5×0.5cm2 square field). The stereotactic diode (SFD) overestimated output factors by 2.5%±0.4%(max.=3.3% for 0.5×1cm2 rectangular field). The other diode detector (Edge) also overestimated the OFs by an average of 4.2%±0.9%(max.=6.0% for 1×1cm2 square field). Gafchromic film (EBT3) measurements and MC calculations agreed with the scintillator detector measurements within 0.6%±1.8% and 1.2%±1.5%, respectively. Across all the X and Y jaw combinations, the average collimator exchange effect was computed: 1.4%±1.1% (CC01), 5.8%±5.4% (SFD), 5.1%±4.8% (Edge diode), 3.5%±5.0% (Monte Carlo), 3.8%±4.7% (film), and 5.5%±5.1% (PSD). Small field detectors should be used with caution with a clear understanding of their behaviors, especially for FFF beams and small, elongated fields. The scintillator detector exhibited good agreement against Gafchromic film measurements and MC simulations over the range of field sizes studied. The collimator exchange effect was found to be important at these small field sizes. Detector-specific correction factors were computed using the scintillator measurements as the benchmark. PACS number(s): 87.56.Fc.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app