OBJECTIVE: To investigate the magnitude of the change in speech-reception threshold (SRT) provided by altering four different test-setup parameters. Furthermore, to determine whether these changes in SRT are of a sufficient magnitude, such that they can be used to design a test-setup in future experiments that target a predefined signal-to-noise ratio (SNR) region. This could be particularly important if the test contrast investigated is confounded with test SNR.
DESIGN: The investigated test-setup parameters were: Spatial separation between target (0°) and maskers (±15°, ±30°, ±45°, or ±75°), number of maskers (two, four or six), scoring method (scoring percent-correct words or sentences) and masker gender (same or opposite to target). Twenty SRTs were measured per test subject.
STUDY SAMPLE: Twenty hearing-impaired test subjects participated over two visits.
RESULTS: Alteration of masker gender, spatial separation between target and masker (±15°, ±30°, ± 45°), and scoring method was shown to offer SRT changes of a sufficient magnitude. The different test setups resulted in average SRTs ranging from -4.0 to 3.3 dB.
CONCLUSION: Deliberately selecting test setup parameters can change the overall difficulty of the test by up to 7.3 dB SRT. Thus, a future experiment can, to this extent, be designed to target a specific SNR region.
DESIGN: The investigated test-setup parameters were: Spatial separation between target (0°) and maskers (±15°, ±30°, ±45°, or ±75°), number of maskers (two, four or six), scoring method (scoring percent-correct words or sentences) and masker gender (same or opposite to target). Twenty SRTs were measured per test subject.
STUDY SAMPLE: Twenty hearing-impaired test subjects participated over two visits.
RESULTS: Alteration of masker gender, spatial separation between target and masker (±15°, ±30°, ± 45°), and scoring method was shown to offer SRT changes of a sufficient magnitude. The different test setups resulted in average SRTs ranging from -4.0 to 3.3 dB.
CONCLUSION: Deliberately selecting test setup parameters can change the overall difficulty of the test by up to 7.3 dB SRT. Thus, a future experiment can, to this extent, be designed to target a specific SNR region.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app