Apneic Oxygenation Versus Low-Tidal-Volume Ventilation in Anesthetized Cardiac Surgical Patients: A Prospective, Single-Center, Randomized Controlled Trial.

OBJECTIVES: To compare the physiology of apneic oxygenation with low-tidal-volume (VT) ventilation during harvesting of the left internal mammary artery.

DESIGN: Prospective, single-center, randomized trial.

SETTING: Single-center teaching hospital.

PARTICIPANTS: The study comprised 24 patients who underwent elective coronary artery bypass grafting surgery.

INTERVENTIONS: Apneic oxygenation (apneic group: 12 participants) and low-VT ventilation (low-VT group: 12 participants) (2.5 mL/kg ideal body weight) for 15 minutes during harvesting of the left internal mammary artery.

MEASUREMENT AND MAIN RESULTS: The primary endpoint was an absolute change in partial pressure of arterial carbon dioxide (PaCO2 ). Secondary endpoints were changes in arterial pH, pulmonary artery pressures (PAP), cardiac index, and pulmonary artery acceleration time and ease of surgical access. The mean (standard deviation) absolute increase in PaCO2 was 31.8 mmHg (7.6) in the apneic group and 17.6 mmHg (8.2) in the low-VT group (baseline-adjusted difference 14.2 mmHg [95% confidence interval 21.0-7.3], p<0.001). The mean (standard deviation) absolute decrease in pH was 0.15 (0.03) in the apneic group and 0.09 (0.03) in the low-VT group baseline-adjusted difference 0.06 [95% confidence interval 0.03-0.09], p<0.001. Differences in the rate of change over time between groups (time-by-treatment interaction) were observed for PaCO2 (p<0.001), pH (p<0.001), systolic PAP (p = 0.002), diastolic PAP (p = 0.023), and mean PAP (p = 0.034). Both techniques provided adequate ease of surgical access; however, apneic oxygenation was preferred predominantly.

CONCLUSIONS: Apneic oxygenation caused a greater degree of hypercarbia and respiratory acidemia compared with low-VT ventilation. Neither technique had deleterious effects on PAP or cardiac function. Both techniques provided adequate ease of surgical access.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app